background image

T2 Telco Accelerator Card

User Guide

UG1496 (v1.0) June 15, 2022

Xilinx is creating an environment where employees, customers, and
partners feel welcome and included. To that end, we’re removing non-
inclusive language from our products and related collateral. We’ve
launched an internal initiative to remove language that could exclude
people or reinforce historical biases, including terms embedded in our
software and IPs. You may still find examples of non-inclusive
language in our older products as we work to make these changes and
align with evolving industry standards. Follow this 

link

 for more

information.

Содержание XILINX T2 Telco

Страница 1: ...language from our products and related collateral We ve launched an internal initiative to remove language that could exclude people or reinforce historical biases including terms embedded in our soft...

Страница 2: ...22 Chapter 6 Xilinx Design Constraints XDC File 23 Appendix A Regulatory Compliance Statements 24 FCC Class A Products 24 Safety 24 EMC Compliance 25 FCC Class A User Information 25 VCCI Class A Stat...

Страница 3: ...C ZU48DR device supporting the following targeted applications 5G NR physical layer functional offload including but not limited to Low density parity check LDPC encoding and decoding Rate matching an...

Страница 4: ...an overview of the hardware features Figure 2 T2 Card High Level Block Diagram Zynq UltraScale RFSoC SC MSP432 Power Supply Unit NOR Flash PL DDR Controller Bank 67 68 69 PS MIO Bank 500 PL GTY PCIe 4...

Страница 5: ...er with the provided host software installation supports the following functions PCIe Gen3 x16 interface User flash image update SC firmware update DDR4 PL BERT performance and diagnostics test DDR4 P...

Страница 6: ...Figure 3 Zynq UltraScale RFSoC XCZU48DR Device Chapter 1 Introduction UG1496 v1 0 June 15 2022 www xilinx com T2 Telco Accelerator Card User Guide 6 Send Feedback...

Страница 7: ...n between server BMC and T2 SC and implements a thermal closed loop control mechanism for card cooling All required telemetry data including board temperatures and power consumption is available In ba...

Страница 8: ...rovided through the maintenance port See Chapter 4 Maintenance Port for details LED A green power on LED is present on the I O bracket to indicate the card is powered and in operation Chapter 2 Featur...

Страница 9: ...on requires x8 bifurcation to be enabled whereas Gen 3 x16 requires x16 mode PCIe Interface Pins The following table summarizes the ZU48DR PCIe interface pin map Table 1 PCIe Interface Pin Map Pin Num...

Страница 10: ...P PCIe RX Data 10 P I F37 PCIE_RX11_N PCIe RX Data 11 N I F36 PCIE_RX11_P PCIe RX Data 11 P I E39 PCIE_RX12_N PCIe RX Data 12 N I E38 PCIE_RX12_P PCIe RX Data 12 P I D37 PCIE_RX13_N PCIe RX Data 13 N...

Страница 11: ...CIe TX Data 12 P O C34 PCIE_TX13_N PCIe TX Data 13 N O C33 PCIE_TX13_P PCIe TX Data 13 P O B32 PCIE_TX14_N PCIe TX Data 14 N O B31 PCIE_TX14_P PCIe TX Data 14 P O A34 PCIE_TX15_N PCIe TX Data 15 N O A...

Страница 12: ...dress 13 O E14 PL_DDR4_1_BA0 DDR4 Bank Address 0 O H13 PL_DDR4_1_BA1 DDR4 Bank Address 1 O F14 PL_DDR4_1_BG0 DDR4 Bank Group 0 O C12 PL_DDR4_1_DM0 DDR4 Data Mask 0 O N14 PL_DDR4_1_DM1 DDR4 Data Mask 1...

Страница 13: ...nal F16 PL_DDR4_1_DQ25 DDR4 Data I O 25 Bidirectional G18 PL_DDR4_1_DQ26 DDR4 Data I O 26 Bidirectional E16 PL_DDR4_1_DQ27 DDR4 Data I O 27 Bidirectional H18 PL_DDR4_1_DQ28 DDR4 Data I O 28 Bidirectio...

Страница 14: ...ECC Bidirectional G20 PL_DDR4_1_DQ65 DDR4 Data I O 65 ECC Bidirectional E23 PL_DDR4_1_DQ66 DDR4 Data I O 66 ECC Bidirectional E21 PL_DDR4_1_DQ67 DDR4 Data I O 67 ECC Bidirectional F24 PL_DDR4_1_DQ68...

Страница 15: ...K13 PL_DDR4_1_CKE DDR4 Clock Enable O F11 PL_DDR4_1_CS DDR4 Chip Select O D14 PL_DDR4_1_WE DDR4 Write Enable O J10 PL_DDR4_1_ALERT DDR4 Alert I J14 PL_DDR4_1_RST DDR4 Reset O J13 PL_DDR4_1_TEN DDR4 T...

Страница 16: ...M3 DDR4 Data Mask 3 O AR38 PS_DDR4_1_DM4 DDR4 Data Mask 4 O AV22 PS_DDR4_1_DQ0 DDR4 Data I O 0 Bidirectional AW24 PS_DDR4_1_DQ1 DDR4 Data I O 1 Bidirectional AW23 PS_DDR4_1_DQ2 DDR4 Data I O 2 Bidirec...

Страница 17: ...Bidirectional AP36 PS_DDR4_1_DQ35 DDR4 Data I O 35 ECC Bidirectional AT39 PS_DDR4_1_DQ36 DDR4 Data I O 36 ECC Bidirectional AP35 PS_DDR4_1_DQ37 DDR4 Data I O 37 ECC Bidirectional AR36 PS_DDR4_1_DQ38...

Страница 18: ...The dual QSPI mode flash has been implemented with two 2 Gb SPI NOR flash devices Micron MT25QU02GCBB8E12 0AAT The MT25QU02GCBB8E12 0AAT NOR flash devices are automotive grade for thermal design reaso...

Страница 19: ...is asserted by the Zynq UltraScale RFSoC to acknowledge the power reduction request by the SC and to avoid a fatal power cutoff protection mechanism The SC is always powered UART Maintenance Port Acc...

Страница 20: ...a 0 Bidirectional R27 RF_QSPI_UPR_DQ1 QSPI Upper Data 1 Bidirectional V27 RF_QSPI_UPR_DQ2 QSPI Upper Data 2 Bidirectional P28 RF_QSPI_UPR_DQ3 QSPI Upper Data 3 Bidirectional H26 PS_SOC_SCL I2C Bus to...

Страница 21: ...FSoC PS applications as required JTAG to RFSoC This JTAG chain to the RFSoC can be used for communication with the Vivado Design Suite during development for programming and debug UART to SC This UART...

Страница 22: ...hat this 40A maximum current limit for the combined VCCINT and SD FEC rails is observed at the maximum operating junction temperature of 100 C The card protection circuit initiates a fatal shutdown if...

Страница 23: ...d card XDC file is available for download from the T Series lounge Contact your Xilinx representative for access Note There are production and prototype versions of the XDC Ensure that you have select...

Страница 24: ...isted in this document IEC 62368 1 2nd Edition 2014 A11 2017 Information technology equipment Safety Part 1 General requirements EN 62368 1 2nd Edition 2014 A11 2017 Information technology equipment S...

Страница 25: ...adiated and Conducted Emissions Australia New Zealand Article 58 2 of Radio Waves Act Clause 3 Korea Regulatory Compliance Markings When required these products are provided with the following product...

Страница 26: ...pment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this e...

Страница 27: ...On Windows select Start All Programs Xilinx Design Tools DocNav At the Linux command prompt enter docnav Xilinx Design Hubs provide links to documentation organized by design tasks and other topics wh...

Страница 28: ...2 Xilinx shall not be liable whether in contract or tort including negligence or under any other theory of liability for any loss or damage of any kind or nature related to arising under or in connect...

Страница 29: ...EATURE CONSISTENT WITH THE ISO 26262 AUTOMOTIVE SAFETY STANDARD SAFETY DESIGN CUSTOMER SHALL PRIOR TO USING OR DISTRIBUTING ANY SYSTEMS THAT INCORPORATE PRODUCTS THOROUGHLY TEST SUCH SYSTEMS FOR SAFET...