Page 9 of 13
4.
Multi protective function
4.1.
Frost Protection Function:
In cooling, dehumidification or economic power saving mode, if the
temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if
the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to
normal operation.
4.2.
Overflow Protection Function:
When the water in the internal water tank exceeds the warning
level, the machine will automatically sound an alarm, and the LCD temperature display area will show
"FL". At this point, you need to move the drainage pipe connecting the machine or the water outlet to
sewer, other drainage area or a flat tray to empty the water (details see
Drainage Instruction
s at the
end of this chapter). After the water is emptied, the machine will automatically return to the original
state.
4.3.
Automatic Defrosting (cooling models have this function):
The machine has automatic
defrosting function: during defrosting, heating symbol on the display screen will flash.
4.4.
Automatic Thermal Protection:
To protect the service life of the machine, the machine has
automatic thermal protection in heating mode. During the protection period, the compressor and the
lower motor will stop operation and will automatically return to normal heating state after the
temperature of the machine recovers.
4.5.
Protection Function of the Compressor:
To increase the service life of the compressor, it has a 3-
minute delay start protection function
EMPTYING THE WATER CONTAINER
1.
Manual drainage:
1.1
When the internal water tank is full the unit will stop working.
1.2
Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to
may cause the internal water tank to spill out.
1.3
Place a tray under the water plug or place the unit in a drainage area.
1.4
Screw off the drain plug and unplug the water rubber stopper - water will drain from the
container.
1.5
Put the water rubber stopper back and screw the drain plug cap back into place.
2.
Continuous drainage:
2.1
Screw off the drain plug cap and unplug the water rubber stopper.
2.2
Use a water pipe to connect to the water outlet.
2.3
You can plumb this pipe into your current plumbing system,
lead it outside and use gravity fall or use a water pump.
Note:
This model has a self-evaporative function, which reduces the need to empty the water tank. If the unit
is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please
do not use continuous drainage if you intend to use the self-evaporating facility.
Содержание SF 8000E
Страница 4: ...Page 4 of 13 PARTS ...