Amcor SF 8000E Скачать руководство пользователя страница 8

Page 8 of 13 

ON/OFF (7) 

· Press “POWER” to switch the unit On or Off 
· The unit will be turn to cooling mode preset to 22

o

C target temperature. Press again and the unit will 

switch off. 
 

Mode button (6) 

· Press this key to choose Cooling Fan, SLEEP or Dehumidifying Mode.   
 

Cooling Mode 

· After machine turns on, default value is cooling mode with 22

o

C and low fan speed. 

· Press “MODE” to select cooling mode, cooling mode indictor 

(C)

 turns on 

· Press “UP

” 

(2)

    or “DOWN

” 

(3)

 to adjust temperature (from 16

o

C to 31

o

C) 

· Press “FAN” to select fan speed (low, high) 
 

Fan Mode 

· Press “MODE” to select fan mode, fan mode indicator 

(D) 

turns on 

 
Timer Mode (1) 

· Under standby mode, press “TIMER” to setup the power-on time, press “TIMER” to adjust the timer (from 

1 to 24 hours). Timer indicator turns on. Unit will start after selected number of hours. 

· Under power on mode, press “TIMER” to setup power-off timer. Press “TIMER” to adjust the timer (from 1 

to 24 hours). Timer indicator turns on. Unit will stop after selected number of hours. 

· Timer functions cannot be combined or repeated. Timer mode indicator 

(I) 

turns on 

 
Sleep Mode   

· Press Mode button 

(6) 

until unit enter into sleep mode, default value of fan speed is low. Sleep mode 

indicator 

(E) 

turns on 

· When the sleep mode is turned on, under cooling mode only, one hour later, set temperature will go up 1 

degree Celsius, after another hour the set temperature will go up another degree than kept at this 
temperature. 

· Sleeping mode is invalid under dehumidifying and fan mode.   
· If internal tank full, machine standby and mode selection, sleeping mode will be cancelled. 

Note:

 Sleep mode is not operational in the dehumidifying or Fan mode. 

 

Compressor Protection 

· There is a three minutes compressor start delay after power on or restart. 

 

3.

 

Remote Control 

The  air  conditioner  can  be  controlled via  a  remote  control. Two  AAA-batteries  are  required  to  use  the  remote 
control.   

Note: 

the air flow direction cannot be adjusted with the remote control. 

1. 

Power:

 Press the 

  key to turn on or turn off the machine 

2. 

Timer:

 Press the 

  key to set the timer 

3. 

Down:

 Press the 

  key to decrease temperature and timer 

4. 

Mode:

 Press the 

  key to switch between cooling, fan, dehumidifier   

5.

 Up:

 Press the 

  key to increase temperature and timer 

6. 

Fan:

 Press the 

  key to select high / low fan speed 

7. 

Sleep Mode:

 Press the 

  key to turn on the sleep mode 

 

 

Содержание SF 8000E

Страница 1: ...CONDITIONER USER MANUAL Thank you for choosing Amcor Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www amcoruk com for our entire range of air conditioners ...

Страница 2: ...tallation 5 FEATURES AND OPERATION 7 1 FEATURES 7 2 OPERATION 7 3 Remote Control 8 4 Multi protective function 9 EMPTYING THE WATER CONTAINER 9 Maintenance 10 Cleaning 10 End of Season Maintenance 10 Troubleshooting 11 APPENDIX 12 TECHNICAL DATA 12 ...

Страница 3: ...damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by an authorised service representative Failure to comply could result in a voided warranty Do not use the appliance for any other purposes than its intended use The air conditioner unit must always be sto...

Страница 4: ...Page 4 of 13 PARTS ...

Страница 5: ... connector on to the hose 2 Assemble the exhaust hose to the air conditioner body Extend one head of the hose and screw it into the unit anti clockwise The hose can be removed by screwing the hose clockwise 3 In the same way connect the hose to the assembled adaptor at least three rotations 4 Installation of window kits Partially open the window and then fix the window kit to the window 5 Make sur...

Страница 6: ...all duct By properly venting you expel hot air from your room while efficiently cooling it Your air conditioner can be used without venting in dehumidifier mode Please ensure external water tank is used monitored and regularly emptied before over spilling Permanent plumbing can be also installed in dehumidifier mode or external uplift water pump for unattended use Important safeguards The length o...

Страница 7: ...r extended life span 2 OPERATION Selection Keys and Display Indicator LED 1 Timer Selection A Cooling Mode 2 Up temperature timer B Dehumidifier Mode 3 Down temperature timer C Heating Mode certain models only 4 Control Panel Screen D Fan mode 5 Fan Mode E Sleep mode 6 Mode Selection F Fan swing mode certain models only 7 Power On Off G Celsius temperature H Tank Full indicator light I Timer on in...

Страница 8: ...turns on Sleep Mode Press Mode button 6 until unit enter into sleep mode default value of fan speed is low Sleep mode indicator E turns on When the sleep mode is turned on under cooling mode only one hour later set temperature will go up 1 degree Celsius after another hour the set temperature will go up another degree than kept at this temperature Sleeping mode is invalid under dehumidifying and f...

Страница 9: ...n period the compressor and the lower motor will stop operation and will automatically return to normal heating state after the temperature of the machine recovers 4 5 Protection Function of the Compressor To increase the service life of the compressor it has a 3 minute delay start protection function EMPTYING THE WATER CONTAINER 1 Manual drainage 1 1 When the internal water tank is full the unit ...

Страница 10: ...vaporator filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean B Clean the lower filter screen frame a Hold the handle of the air inlet filter screen frame and pull it outward gently to remove it b Put the filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean End of Season Maintenance 1...

Страница 11: ...e other sources of heat e g fridges Close doors and windows increase air conditioning power The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions make sure venting is correct as described in this user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard p...

Страница 12: ...ng your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SF8000E V2 Capacity Cooling 2 06kWh 7000BTU Rated Input 760W Running Current 3 9A Air Flow 330m h EER rate A Compressor Rotary R410A gas Noise 38 48dB A Sound Energy 65dB A Sound Power Thermostat 16 31 Moisture removal 20L Day Permitted Excessive Operating Pressure 0 ...

Страница 13: ...call 0871 620 1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full Office hours 9AM 5PM Monday to Friday www amcoruk com Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX ...

Отзывы: