20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
81
TASK 1
I
NSTALLING
THE
SMD34K
1.1 Location
1.1.1 IP64 Rated Units (SMD34K-M12S)
SMD34K units that are IP64 rated are suitable for use in an industrial environment that meet the following
criteria:
Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to
condensation is to be expected
Transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insu-
lation.
These criteria are equivalent to the
Pollution Degree 3
and
Over Voltage Category II
designations of the Inter-
national Electrotechnical Commission (IEC).
1.1.2 IP65/67 Rated Units (SMD34K-M12P)
SMD34K units that are IP67 rated are suitable for use in an industrial environment that meet the following
criteria:
Continuous conductivity occurs due to conductive dust, rain, or other wet conditions.
Transient voltages are controlled and do not exceed the impulse voltage capability of the product’s insu-
lation.
These criteria are equivalent to the
Pollution Degree 4
and
Over Voltage Category II
designations of the Inter-
national Electrotechnical Commission (IEC).
1.2 Safe Handling Guidelines
1.2.1 Prevent Electrostatic Damage
Electrostatic discharge can damage the SMD34K. Follow these guidelines when han-
dling the unit.
1) Touch a grounded object to discharge static potential before handling the unit.
2) Work in a static-safe environment whenever possible.
3) Wear an approved wrist-strap grounding device.
4) Do not touch the pins of the network connectors or I/O connector.
5) Do not disassemble the unit
6) Store the unit in its shipping box when it is not in use.
1.2.2 Prevent Debris From Entering the Unit
While mounting devices, be sure that all debris (metal chips, wire strands, tapping liq-
uids, etc.) is prevented from falling into the unit, specifically into the M12 connectors.
Debris may cause damage to the unit or unintended machine operation with possible
personal injury.
1.2.3 Remove Power Before Servicing
Remove power before removing or installing any SMD34K units in a hazardous envi-
ronment.
Содержание SMD34K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S280 ...
Страница 6: ...TABLE OF CONTENTS SMD34K User Manual ADVANCED MICRO CONTROLS INC 6 Notes ...
Страница 50: ...CALCULATING MOVE PROFILES SMD34K User Manual ADVANCED MICRO CONTROLS INC 50 Notes ...
Страница 62: ...CONFIGURATION DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 62 Notes ...
Страница 80: ...COMMAND DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 80 Notes ...
Страница 100: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...