Data Format (continued)
Notes on Other Configuration Words
Changes to the Idle Current only take effect at the
end of the first move after re-configuration
.
Invalid Configurations
The following configurations are invalid:
1) Setting any of the reserved bits in the configuration words.
2) Setting any parameter to a value outside of its valid range.
3) Configuring the two inputs to have the same function, such as two CW Limit Switches. (An error
does not occur if both are configured as General Purpose Inputs.)
4) Setting the
Stall Detection Enable Bit
without configuring the SMD34K to use its built in encoder.
5) Setting the Input Configuration bits for any input to “111”. See table R5.3 on page 59 for more
information.