Programming Blocks
The following blocks are used to program an Assembled Move. Both of the moves, Blend Move, and Dwell
Move, are programmed exactly the same way. The bit configuration used when starting the move determines
which type of Assembled Move is run.
First Block
Table R7.19 Assembled Move First Programming Block
Unused words are ignored by the Networked Driver and can be any value, including parameter values from
the previous command.
Once the first block is transmitted, the Networked Driver responds by setting bits 8 and 9 in Status Word 0. (See
starting on page 83.) Once these are set, you can then start transmitting Segment Blocks.
Segment Block
Table R7.20 Assembled Move Segment Programming Block
Note that each Segment Block starts with bits 11 and 12 set in the Command Word 0 word (16#1800). When the
Networked Driver sees bit 12 of Command Word 0 set, it will accept the block and reset bit 9 in Status Word 0.
When your program sees this bit reset, it must respond by resetting bit 12 of Command Word 0. The Networked
Driver will respond to this by setting bit 9 in Status Word 0 and the next Segment Block can be written to the
Networked Driver. You can write a maximum of sixteen Segment Blocks for each Assembled Move.
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#0800
1
1025
2
1026
Unused
See Note Below
3
1027
Unused
See Note Below
4
1028
Unused
See Note Below
5
1029
Unused
See Note Below
6
1030
Unused
See Note Below
7
1031
Unused
See Note Below
8
1032
Unused
See Note Below
9
1033
Unused
See Note Below
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#1800
1
1025
2
1026
Rel. Target Position: Upper Word
Steps
Combined value between
–8,388,608 and +8,388,607
3
1027
Rel. Target Position: Lower Word
4
1028
Programmed Speed: Upper Word
Steps/Second
Combined value between
the Configured Starting
Speed and 2,999,999
5
1029
Programmed Speed: Lower Word
6
1030
Acceleration
Steps/ms/sec
1 to 5000
7
1031
Deceleration
Steps/ms/sec
1 to 5000
8
1032
Unused
See Note Below
9
1033
Acceleration Jerk
0 to 5000
Содержание SD17060E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S172 E2 Technology E2 Technology...
Страница 10: ...ABOUT THIS MANUAL Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 22: ...UL CUL RECOGNIZED INSTALLATIONS Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 22 Notes...
Страница 54: ...CALCULATING MOVE PROFILES Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Страница 88: ...COMMAND MODE DATA FORMAT Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 106: ...INSTALLING AN AMCI NETWORKED DRIVER Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 106 Notes...
Страница 130: ...ETHERNET IP EXPLICIT MESSAGING Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 130 Notes...
Страница 134: ...MODBUS TCP CONFIGURATION Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 134 Notes...
Страница 144: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...