CARD DESCRIPTION - EXAMPLE OF A CONNECTION TO AN EXCHANGE

Out1= no 220V

Note: in the example shown in the figure, the dialer is powered by fixed charges from the exchange, the free exchange of the alarm 
relay is connected to input 1, the OPEN-COLLECTOR 1 output is configured as the absence of an electrical netwrok and is connected 
to input 2.

- = power supply 13.8Vcc 

L  1-2-3-4-5 = Lines   inputs / outputs 

-- Configured like Inputs, refer to NEGATIVE --  Configured like outputs, they 

give a NEGATIVE when they are activated

RES = reset of the calls in progress  (OPEN TO RESET) 

-- Referred to NEGATIVE --

PHONE = emulation of a wired telephone line

Содержание VOXOUT

Страница 1: ...ith voice guidance local programming from keyboard remote programming via sms output enabling via ring with confirmation ring 5 selectable lines that can be freely programmed as inputs or outputs Doub...

Страница 2: ...level 3 without the authorization of users at level 2 NOTE for CIE with grade upper to 1 and or when there are 2 or more inputs like robbery the device of tran smission of alarms can not be used avail...

Страница 3: ...e duration Of the outgoing calls CANCEL x TO RECORD ENTER V TO LISTEN AGAIN Time in sec between one attempt and the next call attempt Call attempts made in case phonecalls have not been successful Num...

Страница 4: ...ated output the output must have function U OUTPUT MENU Function Pulse duration Associate Telephones USER CODE MENU User types 01 User Nr 01 M Program Codes CODE User Nr xx 111111 default UT01 Reset C...

Страница 5: ...hold EURO 3 MENU VARIOUS PARAMETERS Life Test 0 Answ Ring 3 Event Delay 5 Value expressed in hours Time in seconds of the inhibition of an input after a first opening Board Tamper 0 0 disabled 1 enabl...

Страница 6: ...n assigned CHANGE PERSONAL CODE CODE User No xx 111111 Cod USER DEFAULT 111111 01 Line 01 D Key to enable outputs Key to disable outputs Attention The functions Medical Aid key arrow left and Fire key...

Страница 7: ...ose 1 to Enable Disable Out 2 Choose 1 to Enable Disable Out 5 Wait Input name enabled disabled System enabled reset closed System disabled reset open Incorrect OK Welcome Choose 1 to enable the envir...

Страница 8: ...alarm relay is connected to input 1 the OPEN COLLECTOR 1 output is configured as the absence of an electrical netwrok and is connected to input 2 SUPPLY power supply 13 8Vcc L 1 2 3 4 5 Lines inputs o...

Страница 9: ...instead the system is updating the information with the provider By pressing the CANC X key again you will shift to the display if available of the entire SMS received from the Provider NOTE The avai...

Страница 10: ...er supply press the key and keep it pressed to resume power supply The dialer will ask you to choose the language ITALIAN or foreign language and will then run the initialization and will restore all...

Страница 11: ...menu With this option the user will not have to type in any code to access his menu C automatic reset of call que If the call to the telephone number with this option is successful the que of the rema...

Страница 12: ...ates that our phone called by the dialer will ring for 30 seconds after which the dialer will hang up and will restart with the next call cycle We recommend a minimum value of 50 seconds NUMBER OF ATT...

Страница 13: ...MENU OF OUTPUTS FUNCTION IT IS possible to program the output with the following functions output disabled A it is enabled by following the assoicated input only with reset terminal closed H it is en...

Страница 14: ...NTER CONTACT ID MENU IDC AND SYSTEM NUMBERS IDC numbers It is possible to insert 8 telephone numbers to which send the report code Press ENTER insert the number confirm with ENTER with the up and down...

Страница 15: ...t For the other providers it s needed to set phone number keyword SMS text to send to the provider Note it s possible to use a KEYWORD to identify the value for credit to visualize on display This wor...

Страница 16: ...mediately sent out To re open the same input within the pro grammed10 seconds the second signal will not leave immediately but once the 10 seconds have lapsed Once you have accessed the menu press ENT...

Страница 17: ...e the buzzer from the keys allow the installer to reprogram the dialer from remote USE OF THE SMS FOR PROGRAMMING PURPOSES The SMS to be sent must have a precise structure and must always be preceded...

Страница 18: ...K OFF this command unlocks the programming via sms for 20 minutes 111111 is the default pwd If the installer must for example assign the type ALARM input to input 2 he will send an SMS giving his pass...

Страница 19: ...TIME OF THE ATTEMPTS in seconds from 0 to 240 VOXREPEAT VOICE MESSAGE REPETITIONS max 9 VOXWAIT ANSWER WAIT in seconds from 0 to 60 RINGSNR RINGS BEFORE ANSWER max 10 OUTTEL ASSOCIATION OF TELEPHONES...

Страница 20: ...in the case of limitations and or problems due to faultiness in the service offered by the network provider TECHNICAL SPECIFICATIONS Power supply 13 8Vcc 0 7 Vcc Current in standby 150mA Maximum curre...