SRL400/R  V1.0 EN

The buzzer board features 2 signaling LED, a battery connector and 2 power supply terminals:

RED LED (POWER SUPPLY CHECK) 

 

- Off: the buzzer is not powered

 

- Brief flash every 4 seconds: in standby operating mode

 

- Steady on: the battery is recharging

 

- Fast flash: the battery is not connected, is faulty or is dead

 

- Slow flash: recharging voltage missing

GREEN LED (RADIO PART SYSTEM AND CHECK): 

 

- Steady on: no linked transmitter (buzzer not programmed)

 

- Steady on for 1 second: status transmitter toward CS400. (ALL OK)

 

- Fast flash for 1 second: control signal reception from CS400 (ALL OK)

 

- Slowly flashes during self-learning phase (see below)

CONNECTING THE POWER SUPPLY TERMINALS: 

 

- Connect a power to the + - terminals (see figure) having an output voltage between 10 - 15 Vcc 200mA

POLARIZED BATTERY CONNECTOR: 

 

- Connect the battery pack included in the buzzer package (TYPE Ni-MH 700mAh 7.2Vcc)

 ASSEMBLY OF BUZZER SHELL AND ACCESSORIES

An installation according to standard requires the use of a screw fastened to a wall, whose head must exert pressure on the anti-

removal microswitch, located on the lower side of the board.

Note: bending the metal tab of the microswitch to achieve the same purpose nullifies the certification.

 