background image

www.amcelettronica.com 

IF400T - v 1.0

 

the detector active avoiding the return in the rest state. If, on the contrary, during this period it doesn’t 
detect any movement it will return to the rest state ready to send another signal. The return to the rest 
state is notified by a LED’s very fast blink, almost imperceptible to optimize the batterie’s consumption. 
The test mode is automatically activated during the first ignition, the duration is 20 cycles (the detector 
will not rest but it will restore 10/20 seconds after each violation for a total of 20 times. After the counting, 
if it is violated during the restoration, the detector will stand-by for about 2min30sec. To return the sensor 
in test mode simply open and then reseal the anti-opening tamper switch.

 

NORMAL MODE Working:

 

Finished the test phase (50 cycles of transmission without going in stand-by), after the first detection 
with radio signal transmission, begins the counting time of 20 seconds during which the detector will try 
to return in the rest state. If, at the end of counting, the detector will not be returned in the rest state, due 
to  continuous  detections,  will  start  a  2.5  minutes  period  of  inhibition  in  POWER  SAFE  mode,  during 
which the  detector can  no longer send alarm detection radio signals (anyway it remains active for all 
other alerts). Each movement detected during  the period of inhibition  will prolong the same other 2.5 
minutes. The end of the period of inhibition is indicated by a LED’s fast blink.

 

INSTALLATION 

- Unscrew the closing screws and fix the housing in the desired mounting place.

 

To  program  the  device  into  the  receiver, 

insert  the  battery  in  the  proper  space, 
following  the  right  polarity,  and  then  use 
the  LEARN  Button  to  send  the  Learning 
Signal to the receiver.

 

Note: For the complete procedure 

please refer to the Receiver’s Manual.

 

To  let  become  active  the  DIP-SWITCH 

configuration  press  the  LEARN  Button 
and check if the LED blinks fast.

 

Once  placed  the  device  in  the  desired 

position  please  use  the  Receiver’s  Test 
Tools to check the radio range, the perfect 
box closure, the battery level etc. 

 

Please refer to the Receiver’s Manual.

 

ADJUSTMENTS AND FUNCTIONAL NOTES 

This detector is been designed to be installed as passages protection, for example between window and 
shutter and/or rolling shutter, otherwise to protect doors and main doors. So for the correct installation 
needs  to  be  considered  the  lens  position  that  must  always  be  oriented  downward  (Fig.3).  Is  also 
important the range adjustment that must be the most similar to the desired real coverage. Acting to the 
RANGE Trimmer in Clockwise direction the range will be increased (Fig.1). Please keep in mind that 
during the installation is possible that the detector needs to be oriented and/or tilted a little to satisfy the 
coverage requirements (Fig.3).

 

 

Unscrew Here to Open

 

Fig. 2

 

Отзывы: