DIP - SWITCH:
OFF
ON
1
Acoustic signalation (buzzer) disabled
Acoustic signalation (buzzer) enabled
2
Creep zone (terminals side) disabled
Creep zone (terminals side) enabled*
3
Creep zone (terminals opposite side) disa-
bled*
Creep zone (terminals opposite side) enabled*
4
normal sensitivity
High sensitivity**
5
Anti-opening and anti-removal enabled
Anti-opening and anti-removal disabled
disabilitati
6
Anti-removal enabled
Anti-removal disabled
* This function is used to allow small pets to pass through a protected window or door, when the alarm system is
armed.
** This parameter reduces the reaction time of the Active IR beams, therefore it is suggested to use it with care and in
places not directly exposed to sunbeams.
*** The plugs are not completely waterproof in order to avoid condensed water to stay inside and allow the beams to
transpire.
5. TRANSMITTER DIP-SWITCH CONFIGURATION - RANGE ADJUSTMENT
7. RECEIVER DIP-SWITCH CONFIGURATION:
DIP - SWITCH
5 LINES
(FIG2):
DIP
1
DIP
2
DIP
3
INDOOR
OUTDOOR
OUTDOOR WIHT SUN
DIP
off
off
off
0.5
⇨ 6 m
0.5
⇨ 2 m
0.5
⇨ 2 m
off
off
on
6
⇨ 8 m
2
⇨ 4 m
2
⇨ 3 m
off
on
on
8
⇨ 12 m
4
⇨ 6 m
3
⇨ 6 m
on
off
off
12
⇨ 15 m
6
⇨ 12 m
6
⇨ 10 m
DIP 4
⇒ on
antiremoval disabled
⇒ off
antiremoval enabled
DIP 5
⇒ on
antiremoval and anti-opening disabled
⇒ off
antiremoval and anti-opening enabled
6. TRANSMITTER CONFIGURATION DIP-SWITCH: SETTING OF OPTICAL NUM.
DIP 1
DIP 2
DIP 3
N° OTTICHE
DIP 1
DIP 2
DIP 3
N° OTTICHE
Off
Off
Off
2
On
Off
Off
6
Off
Off
On
3
On
Off
On
7
Off
On
Off
4
On
On
Off
8
Off
On
On
5
On
On
On
8
DIP - SWITCH
3 LINES (FIG.2):
Attention
: after the configuration of DIP, power OFF and then power ON
the barriers to confirm the configuration