10. Technical parameters
PARAMETER
VALUE
sensor type
DX: IEPE, 100 mV/g , 8 mA/20 V
DT: 10 mV/°C
DX: vibration velocity, acceleration
measured values
DT: temperature
types of estimates
RMS, 0-PEAK
power supply
24 VDC (18..36 VDC)
power consumption
<4 W
low-pass filter
DX: 1 and 10 kHz, 24 dB/oct., 4
th
order
DT: no LPF filter
high-pass filter
DX: 3 and 10 Hz, 12 dB/oct., 2
nd
order
DT: no HPF filter
insulation
1 kV DC (2 or 3 kV DC optionally)
current output:
2 or 3 wired 4..20 mA current loop
voltage output
AC, 10V
pp
max
delay
0 - 16s every 1s
alarm level
0 – 99
warning level
0 – 99
relay outputs
24 V/100 mA, NO
operating temperature
-20..+60
o
C
operating relative humidity
<95% RH
protection class
IP20
dimensions
23 x 100 x 120 (W x H x L)
mounting
35 mm DIN rail
15