Ambirad Vision VSX Скачать руководство пользователя страница 6

 

3.3 Burner Removal  

 
Step 1 Isolate power and gas  supplies. 
 

 
Step 2 Unplug the power connectors. 

Step 3 Detach the gas supply as shown below, 
taking care to support the burner connection. 

Step 4 If ducted air is connected, slacken    
hose clip and remove the flexible hose from the 
burner. 

Step 5 slacken the jubilee clip attaching the 
pre-heated air hose to the heat exchanger and 
remove the flexible hose from the burner. 

Step 6 Slacken the set screw on the burner  
support casting to enable the burner to be     
removed from the radiant tube. 

 
Step 7 Remove the burner and position 
the burner in a safe area to prevent the 

burner or components attached to the burner 
from falling to the ground. 

3.4 Burner Gas Injector Servicing 
 

Step 1.a Remove the burner support casting 
and gasket. 

Step 1.b The burner head assembly can be   
disconnected by separating the connectors of 
the ignition lead assembly and removing the 
pressure switch silicon tube. 

Содержание Vision VSX

Страница 1: ...ith the relevant provisions of the Gas Safety Installations and Use Regulations 1998 for gas fired products Due account should also be taken of any obligations arising from the Health and Safety at Wo...

Страница 2: ...t tube heaters specified in these instructions due care 3 9 Reflector Servicing 3 10 Inspection of Flue 3 11 Re commissioning after Service 4 Spare Parts 5 Fault Finding Guide 6 Replacing Parts 6 1 Bu...

Страница 3: ...2 8 2 4 450x5927x746 158 0 5 2560 VSX45UT 44 0 39 6 4 2 11 6 2 9 450x5927x746 158 0 5 2560 VSX50UT 49 5 44 6 4 7 12 8 2 5L 450x7692x746 205 0 5 2560 1 3 Table 1 Technical Details All heaters to run on...

Страница 4: ...nd inspect burner head See servicing instructions Check operation of air pressure switch Leave the instructions with a responsible person Injector pressure test point Adjustment screw under cap to set...

Страница 5: ...Wrench with 13mm Socket 12mm Spanner 3 1 Tools Required The following tools and equipment are advisable to complete the tasks laid out in this manual Suitable alternative tools may be used Large Adjus...

Страница 6: ...nger and remove the flexible hose from the burner Step 6 Slacken the set screw on the burner support casting to enable the burner to be removed from the radiant tube Step 7 Remove the burner and posit...

Страница 7: ...replaced ensuring the 5 holes on the outer ring are aligned alongside the probes Step 3 The condition of the igniter assembly can be checked for deterioration However we advise replacement at each ser...

Страница 8: ...dust with a soft brush Step 6 Remove any dust from fan scroll and from around the motor Step 7 Ensure the impeller rotates freely Step 8 Refit components 3 7 Radiant Tube Servicing Step 1 Brush any d...

Страница 9: ...hanger refit 3 9 Reflector Servicing The condition of the reflectors should be noted If necessary the reflectors can be cleaned with a mild detergent This can significantly improve the efficiency of t...

Страница 10: ...ription See section 1 10 Injector 200358 Extruded Burner Head Item 201284 Ignitor Assembly Part No Description 200988 Pepperpot Head Item 2175 Amber Neon Burner On 2180 Red Neon Mains On 200420 Jet Ca...

Страница 11: ...cuum switch pull in Check 1 Wiring harness plugs 2 Vacuum switch operation 3 Replace fan Is the burner sparking Does the gas valve open Check 1 Burner controller 2 Replace gas valve Check 1 Vacuum swi...

Страница 12: ...tep 5 Fit new burner controller Step 6 Refit HT leads and refit burner controller to wiring harness Step 7 Test product and close access doors 6 2 Air Pressure Switch Replacement Step 1 Disconnect the...

Страница 13: ...impulse tube and the burner head wiring Step 5 From within the combustion chamber remove the two screws holding the front of the gas valve Step 6 Turning the housing over remove the four screws holdin...

Страница 14: ...and a mild detergent non solvent based cleaners only in water can be undertaken Additional removal of dust from the radiant tubes burner and heat exchanger can be undertaken 7 4 Frequency of Servicin...