background image

      4.4 Channel Selection

Press  the 

CH/+

  button  to  switch  the  display  between 

remote sensors 1 through 8, and scroll mode 

 

. In scroll 

mode, all of detected outdoor sensors will be displayed in 
five second intervals.

      4.5 Sensor Search Mode

If  any  of  the  sensor  communication  is  lost,  dashes  (--.-) 
will be displayed on the screen. To reacquire the signal:

1. If a specific channel is lost, press the 

CH/+

 button 

to  display  this  channel,  then  Press  and  hold  the 

CH/+

 button for 

3

 seconds, and the remote search 

icon        will  be  constantly  displayed  for  up  to  3 
minutes. Once the signal is reacquired, the remote 
search icon     will turn off, and the current values 
will be displayed.

2. If new sensors are added, subtracted, or multiple 

sensor channels are lost, press and hold the 

CH/+

 

button for 

5

 seconds (on any channel), and the 

remote search icon       will be constantly displayed 
for up to 10 minutes. Once the signal is reacquired, 
the remote search icon       will turn off, and the 
current values will be displayed.

      4.6 Best Practices for Wireless Communication

Wireless  communication  is  susceptible  to  interference, 
distance,  walls  and  metal  barriers.  We  recommend  the

Version 1.0

     

©Copyright 2013, Ambient  LLC. All Rights Reserved.

     

Page 12

Содержание WS14 F007T

Страница 1: ...nsole Layout Sensor Operation Verification 4 Display Features 4 1 Rate of Change Icon 4 2 1 Set Mode 4 2 2 Viewing the High and Low Alarms 4 2 3 Alarm Defaults 4 2 4 Setting the Min and Max Alarm 4 3 Manually Reset Max Min 4 4 Channel Selection 12 4 5 Sensor Search Mode 4 6 Best Practices for Wireless Communication Ambient Weather WS14 Wireless Indoor Outdoor 8 Channel Thermometer Console Only wit...

Страница 2: ...emperature Calibration 4 7 2 Indoor Temperature Calibration 13 14 15 5 Glossary of Terms 16 6 Specifications 17 6 1 Wireless Specifications 17 6 2 Measurement Specifications 17 6 3 Power Consumption 17 7 Troubleshooting Guide 17 8 Accessories 20 9 Liability Disclaimer 21 10 FCC Statement 22 11 Warranty Information 23 ...

Страница 3: ...also includes an indoor channel there is a sensor inside the display as well as supports up to 8 remote sensors channel 1 is always displayed and 2 8 can be displayed in the sensor temp section of the display The WS14 supports any combination of the following sensors sensors are sold separately http ambientweather wikispaces com WS 14C Item Number Description 8 channel sensor measures temperature ...

Страница 4: ...ce s and the display is outside water t e m p e r a t u r e s o i l temperature and ground temperature F007TP 8 channel pool float thermometer Applications include pools spas and lakes F007PF 2 Getting Started Note The power up sequence must be performed in the order shown in this section insert batteries in the remote transmitter s first Display Console second The WS14 weather station consists of...

Страница 5: ...ights Reserved Page 5 2 1 Parts List 3 Display Console Set Up Move the remote thermometer s about 5 to 10 away from the display console if the sensor is too close it may not be received by the display console If you have more than one thermometer make sure they are all powered up and transmitting on different channels Remove the battery door on the back of the display as shown in Figure 1 ...

Страница 6: ... position with the desk stand folded out The console will instantly display time indoor temperature as designated by the icon The remote temperature will update on the display within a few minutes on the appropriate channel While in the search mode the remote search icon will be constantly displayed If you have more than once remote sensor up to eight remotes are supported the display will automat...

Страница 7: ...icon is no longer on otherwise the remote sensor search mode will be terminated When the remote sensor temperature has been received the console will automatically switch to the normal mode and all further settings can be performed If the remote does not update please reference the troubleshooting guide in Section 8 Display Console Layout Figure 2 3 1 ...

Страница 8: ...rate of change icon detects rapid changes in remote temperature If the arrow points upward the temperature is increasing at a rate of 2 F per 30 minutes or greater If the arrow points downward the temperature is decreasing at a rate of 2 F per 30 minutes or less 4 2 Console Operation Note The console has three buttons for easy operation SET button MIN MAX button and CH button 4 2 1 Set Mode The Se...

Страница 9: ...utton for three seconds to toggle the alarm on and the alarm off The time alarm icon will appear when set and disappear when disabled Press do not hold the SET key to advance to the next setting 5 Alarm Minute Press the or key to increase or decrease the alarm minute While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and the alarm off The time ...

Страница 10: ...nd LOW MIN alarm along with the alarm time Press the SET button again to return to the normal mode 4 2 3 Alarm Defaults 4 2 4 Setting the Min and Max Alarm The high and low alarms can be set for Channels 1 and 2 only Press the CH button to switch the display between Channel 1 and 2 Next press the SET button once and the alarm icon will appear Press and hold the SET button for 3 seconds and the tem...

Страница 11: ...ature alarm The LOW alarm for temperature will flash Press the CH button to increase the LOW alarm and the MIN MAX button to decrease the LOW alarm Press and hold the or button to change rapidly While the alarm value is flashing press and hold the SET button for three seconds to toggle the alarm on and off the alarm The alarm icon will appear when set and disappear when disabled 4 3 Manually Reset...

Страница 12: ...l be constantly displayed for up to 3 minutes Once the signal is reacquired the remote search icon will turn off and the current values will be displayed 2 If new sensors are added subtracted or multiple sensor channels are lost press and hold the CH button for 5 seconds on any channel and the remote search icon will be constantly displayed for up to 10 minutes Once the signal is reacquired the re...

Страница 13: ...t Rating This device is rated at 300 feet line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barriers Radio frequency will not pass through metal barriers such as aluminum siding If you have metal siding align the remote and console through a window to get a clear li...

Страница 14: ...ers They are in a different location and typically update once per hour The purpose of your weather station is to measure conditions of your surroundings which vary significantly from location to location 4 7 1 Remote Sensor Temperature Calibration Prior to entering the calibration mode press the CH button to select the remote temperature sensor you wish to adjust To enter the temperature calibrat...

Страница 15: ...T and MIN MAX buttons at the same time for 5 seconds and the IN TEMP temperature value will begin flashing Press the CH button to increase the temperature and the MIN MAX button to decrease the temperature reading in 0 1 increments To rapidly increase or decrease the temperature reading press and hold the CH or MIN MAX button To return the temperature to the actual or uncalibrated measurement pres...

Страница 16: ...mercury or red spirit fluid thermometer Bi metal dial and other digital thermometers are not a good source and have their own margin of error Using a local weather station in your area is also a poor source due to changes in location timing airport weather stations are only updated once per hour and possible calibration errors many official weather stations are not properly installed and calibrate...

Страница 17: ...asured parameters 6 3 Power Consumption Base station display console 3 x AAA 1 5V Alkaline or Lithium batteries not included Battery life Minimum 12 months for base station with one sensor and excellent reception Intermittent reception and multiple sensors may reduce the battery life 7 Troubleshooting Guide If your question is not answered here you can contact us as follows 1 Email Support 2 Live ...

Страница 18: ...he current values will be displayed The maximum line of sight communication range is 300 and 100 under most conditions Move the sensor assembly closer to the display console If the sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fres...

Страница 19: ... and outdoor temperature sensors should agree within 2 F the sensor accuracy is 1 F Use the calibration feature to match the indoor and outdoor temperature to a known source Display console contrast is weak Replace console batteries with a fresh set of batteries Temperature sensor reads too high in the day time Make sure the thermometer is mounted in a shaded area on the north facing wall Consider...

Страница 20: ...LX Temperature and Humidity Solar Radiation Shield One step calibration kits for digital hygrometers use salt slurry formula to accurately calibrate the indoor and outdoor hygrometers Ambient Weather Humidity Calibration Kits Add additional remote thermometers Supports up to eight remote sensors Ambient Weather F007PF Wireless Water Thermometer for WS14 Weather Stations Add as many display console...

Страница 21: ...y responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of weather conditions This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of ch...

Страница 22: ...CC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in aresidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruct...

Страница 23: ...ns on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by a Ambient LLC The original dated bill of sale must be presented upon request as proof of purchase to Ambient LLC Your A...

Страница 24: ... intended 6 the products inability to receive a signal due to any source of interference or metal obstructions and 7 extreme acts of nature such as lightning strikes or floods This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller...

Отзывы: