1.

 

Introduction 

Thank you for your purchase of the Ambient Weather WS-228TBH 9" Brushed Aluminum Traditional 
Barometer  with  Temperature  and  Humidity,  Radiant  Blue.  The  following  is  a  guide  for  preparation, 
care and operation of your traditional weather station. 

 

2.

 

Preparation 

Your weather instrument includes a protective pad to prevent damage to the barometer mineral glass 
case  during  shipment.  Remove  this  protective  pad  and  circular  instruction  sheet.    The  barometer  is 
ready to use. 

3.

 

Care and Cleaning 

Avoid use of harsh household cleaners and coarse paper towels, which can damage the lacquer coating 
or  scratch the bezel  or lens.  Fingerprints and dirt may be removed the  lenses and bezels with a soft 
cloth lightly dampened with a mixture of water and mild dishwashing liquid.    Be sure to dry the lens 
and bezel with a soft cloth after cleaning. 
 
Do not install the weather station outside. The weather station is intended for indoor use only. 

4.

 

Hygrometer (Humidity Meter) 

4.1

 

How the hygrometer works 

The  hygrometer  measures  the  indoor  relative  humidity.    The  sensor  measures  the air  moisture  by  a 
sensitive mechanical coil spring that is bonded with a moisture absorbent material. 
 
Hygrometers  register  the  percentage  of  water  vapor  present  in  the  air,  compared  to  the  maximum 
amount that can be present at a given temperature. 
 
The  coils  in  hygrometers  respond  slowly  and  while  humidity  levels  change  abruptly,  it  can  take  an 
hour  or  more  for  the  meter  to  reach  an  accurate  reading.  Remember  that  the  hygrometer  is  reading 
indoor  humidity,  and  is  vastly  different  than  outdoor  humidity,  as  reported  by  the  National  Weather 
Service. 
 
It is not uncommon to have low humidity reading during cold weather when indoor air is heater. Air 
conditioning  also  removes  moisture  from  the  air.    The  optimum  levels  are  45%  to  50%  during 
heating  and  cooling  seasons.    Low  humidity  can  cause  health  problems  and  can  be  hard  on  wood 
furnishings. High humidity can cause mold or mildew to grow. 

4.2

 

Hygrometer Accuracy 

 
Humidity  measurement  is  among  the  more  difficult  problems  in  basic  meteorology.  Accuracy  is 
difficult to achieve and are subject to drift, so need regular recalibration.   
 
A further difficulty is that most hygrometers sense relative humidity rather than the absolute amount 
of water present, but relative humidity is a function of both temperature and absolute moisture content, 
so  small  temperature  variations  within  the  air  in  a  test  chamber  will  translate  into  relative  humidity 

Содержание WS-228TBH

Страница 1: ...roduction 2 2 Preparation 2 3 Care and Cleaning 2 4 Hygrometer Humidity Meter 2 4 1 How the hygrometer works 2 4 2 Hygrometer Accuracy 2 5 Aneroid Barometer 3 5 1 How the aneroid barometer works 3 5 2 Reading the barometer 3 5 3 Absolute vs Relative Pressure 3 5 4 Barometer Calibration 4 6 Dial Thermometer 5 7 Installation 5 8 Measurement Specifications 5 9 Warranty Information 5 10 California Pro...

Страница 2: ...sitive mechanical coil spring that is bonded with a moisture absorbent material Hygrometers register the percentage of water vapor present in the air compared to the maximum amount that can be present at a given temperature The coils in hygrometers respond slowly and while humidity levels change abruptly it can take an hour or more for the meter to reach an accurate reading Remember that the hygro...

Страница 3: ...oves sunny to partly cloudy and when the pressure decreases the weather degrades cloudy to rain The weather forecast is an estimation or generalization of weather changes in the next 24 to 48 hours and varies from location to location The tendency is simply a tool for projecting weather conditions and is never to be relied upon as an accurate method to predict the weather The barometer includes a ...

Страница 4: ...fficial reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reporting station 5 4 Barometer Calibration Your barometer will operate from 100 to 3 000 feet with reliable accuracy Aneroid barometers have a small screw on the back for sea level calibration With a flat b...

Страница 5: ... limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by ...

Страница 6: ...nces of concern and instead sets forth a much less definitive standard requiring that the business demonstrate with certainty that there is no significant risk resulting from exposure With respect to carcinogens the no significant risk level is defined as the level which is calculated to result in not more than one excess case of cancer in 100 000 individuals exposed over a 70 year lifetime In oth...

Страница 7: ...pyright 2014 Ambient LLC All Rights Reserved Page 7 warning signs on Ambient Weather Products For further information about California s Proposition 65 please visit https oehha ca gov prop65 background p65plain html ...

Отзывы: