5.2.1 Set Mode 

The Set Mode allows you to set the time and time format, time alarm and units of measure. 
To enter the set mode, press and hold the 

SET

 key for 3 seconds. 

1.

 

12 hr/24 hr time format.

    Press the [+] key to switch between 12 and 24 hour format. Press 

the SET key to advance to the next setting. 

2.

 

Hour

.  Press  the  [+]  or  [-]  key  to  increase  or  decrease  the  hour.    Press  the 

SET

  key  to 

advance to the next setting. 

3.

 

Minute

. Press the [+] or  [-]  key  to  increase or decrease the minute.    Press the 

SET

  key to 

advance to the next setting. 

4.

 

Alarm

 

Hour

. Press the [+] or [-] key to increase or decrease the alarm hour. While the alarm 

value is flashing, press and hold the 

SET

 button for three seconds to toggle the alarm on and   

the alarm  off.  The  time alarm  icon will  appear 

  when set,  and disappear when  disabled.   

Press (do not hold) the 

SET

 key to advance to the next setting. 

5.

 

Alarm

 

Minute

. Press the [+] or [-] key to increase or decrease the alarm minute. While the 

alarm value is flashing, press and hold the 

SET

 button for three seconds to toggle the alarm 

on  and  the  alarm  off.  The  time  alarm  icon  will  appear 

  when  set,  and  disappear  when 

disabled.    Press(do not hold) the 

SET

 key to advance to the next setting. 

6.

 

Temperature  Units  of  Measure

.  Press  the 

[+]

  key  to  switch  between  °F  and  °C  units  of 

measure. Press the 

SET

 key to advance to the next setting. 

7.

 

Max/Min  Clearing

.    The  Max/Min  can  be  programmed  to  clear  daily  (at  midnight)  or 

manually. Press the 

[+]

 key to switch between “Clears Daily” and Clears Manually. Press the 

SET

 key to exit setting. 

5.2.2 Viewing the High and Low Alarms 

The high and low alarms can be set for Channels 1 and 2 only.    Press the 

CH/+

 button to switch the 

display between Channel 1 and 2. 
 

Next,  press  the 

SET

  button to  view  the  High 

(MAX)

  and  LOW 

(MIN)

  alarm  along  with  the  alarm 

time.    Press the 

SET

 button again to return to the normal mode. 

5.2.3 Alarm Defaults 

 

Channel  Default Condition  HI ALARM (temperature) ºF 

LOW ALARM (temperature)ºF 

OFF 

100 

60 

OFF 

110 

90 

5.2.4

 

Setting the Min and Max Alarm 

The high and low alarms can be set for Channels 1 and 2 only.    Press the 

CH/+

 button to switch the 

display between Channel 1 and 2. 
 
Next, press the 

SET

 button once, and the alarm icon will appear: 

. Press and hold the 

SET

 

button for 3 seconds, and the temperature 

HIGH (max) 

alarm will flash.    Press the 

CH/+

 button to 

increase the 

HIGH

 alarm and the 

MIN/MAX

 button to decrease the 

HIGH 

alarm. Press and hold the 

+ or - button to change rapidly. While the alarm value is flashing, press and hold the 

SET

 button for 

three seconds to toggle the alarm on and the alarm off. The alarm icon will appear 

  when set, and 

disappear when disabled. 

 

 

Press (do not hold) the 

SET

 button again to set the 

LOW (min)

 temperature alarm. The 

LOW 

alarm 

for  temperature  will  flash.  Press  the 

CH/+

  button  to  increase  the 

LOW

  alarm  and  the 

MIN/MAX

 

Содержание WS-15

Страница 1: ...nge Icon 8 5 2 Console Operation 8 5 2 1 Set Mode 9 5 2 2 Viewing the High and Low Alarms 9 5 2 3 Alarm Defaults 9 5 2 4 Setting the Min and Max Alarm 9 5 3 Manually Reset Max Min 10 5 4 Channel Selection 10 5 5 Sensor Search Mode 10 5 6 Best Practices for Wireless Communication 10 5 7 Adjustment or Calibration 11 5 7 1 Remote Sensor Temperature Calibration 11 5 7 2 Indoor Console Temperature Cali...

Страница 2: ...e following sensors and receivers additional sensors and receivers are sold separately Item Number Image Description F007T 8 channel sensor measures temperature Applications include indoor and outdoor air temperature measurement F007TP 8 channel sensor measures probe temperature Applications include refrigerators and freezers where the probe is placed inside the appliance s and the display is outs...

Страница 3: ...ermometer remote transmitter 2 1 Parts List QTY Item 1 Probe thermometer transmitter with probe FT007TP Dimensions LxHxW 4 5 x 2 0 x 0 75 1 Display Console Frame Dimensions LxHxW 4 0 x 2 95 x 1 00 in LCD Dimensions LxW 1 96 x 1 77 LCD Segment Height 0 78 inches 1 User Manual 2 2 Probe Thermometer Sensor Set Up Note Use only high quality rechargeable batteries We recommend fresh alkaline batteries ...

Страница 4: ...he inside cover of the lid of the transmitter Figure 2 displays all four switches in the OFF position factory default setting Figure 2 3 Channel Number The sensor supports up to eight transmitters To set each channel number the default is Channel 1 change Dip Switches 1 2 and 3 as referenced in Table 1 4 Temperature Units of Measure To change the transmitter display units of measure F vs C change ...

Страница 5: ...mitting data 7 Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 3 Figure 3 1 temperature 2 temperature units F vs C 3 channel number 8 Close the battery door Make sure the gasket around the battery compartment is properly seated in its trace prior to closing the door Tighten the set screw 3 Remote Sensor Installation The remote prob...

Страница 6: ...6 Use a screw or nail not included to affix the remote sensor to the wall as shown in Figure 4 Note If measuring outside air temperature we recommend mounting the sensor in the shade on the north side of the house or structure to avoid radiant heat transfer Figure 4 ...

Страница 7: ...h quality batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly 1 Replace the battery door and place the console in the upright position with the desk stand folded out The console will instantly display time and indoor temperature as designated The remote temperature will update on the display within a few...

Страница 8: ... temperature match closely in the same location about 5 to 10 apart The sensors should be within 2 F the accuracy is 1 F Allow about 30 minutes for both sensors to stabilize The temperature can be adjusted or calibrated later to match each other or a known source 5 Display Features 5 1 Rate of Change Icon The rate of change icon detects rapid changes in remote temperature If the arrow points upwar...

Страница 9: ...f measure Press the SET key to advance to the next setting 7 Max Min Clearing The Max Min can be programmed to clear daily at midnight or manually Press the key to switch between Clears Daily and Clears Manually Press the SET key to exit setting 5 2 2 Viewing the High and Low Alarms The high and low alarms can be set for Channels 1 and 2 only Press the CH button to switch the display between Chann...

Страница 10: ...emote search icon will turn off and the current values will be displayed 2 If new sensors are added subtracted or multiple sensor channels are lost press and hold the CH button for 5 seconds on any channel and the remote search icon will be constantly displayed for up to 10 minutes Once the signal is reacquired the remote search icon will turn off and the current values will be displayed 5 6 Best ...

Страница 11: ...ch vary significantly from location to location 5 7 1 Remote Sensor Temperature Calibration Prior to entering the calibration mode press the CH button to select the remote temperature sensor you wish to adjust To enter the temperature calibration mode press and hold the SET and CH buttons at the same time for 5 seconds and the remote temperature value will begin flashing Press the CH button to inc...

Страница 12: ... hours Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer 6 Glossary of Terms Term Definition Accuracy Accuracy is defined as the ability of a measurement to match the actual value of the quantity being measured Range Range is defined as the amount or extent a value can be measured 7 Specifications 7 1 Wireless Specifications Line of sight wirel...

Страница 13: ...he sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environments install lithium batteries Make sure the remote sensors are not transmitting through solid metal a...

Страница 14: ...ES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT 10FCC Statement Statement according to FCC part 15 19 This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Statement according...

Страница 15: ... Your Ambient LLC warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect lack of reasonable and necessary maintenance 2 damage resulting from failure to follow instructions contained in your owner s manual 3 damage resulting from the performance of repairs or alterations by someone other than an author...