Ambient Weather WS-1175 Скачать руководство пользователя страница 9

 

Version 1.0  

 

©Copyright 2011, Ambient LLC. All Rights Reserved. 

 

 

 

 

 

Page 9 

turn on for five seconds.

 

4.4 Min/Max Mode 

While in Normal Mode, press the 

MIN/MAX

 key to enter the min/max mode. 

Note: 

If you have multiple remote temperature and humidity sensors, select the Channel you wish 

to view the min/max data before you enter the min/max mode. 
 

1.

 

Maximum  Barometric  Pressure.

  The  maximum  barometric  pressure,  associated  date  and 

time, and the 

MAX

 icon will be displayed. To reset the maximum barometric pressure to the 

current pressure, press and hold the 

MIN/MAX

 key for two seconds. 

 

2.

 

Minimum  Barometric  Pressure.   

Press  the

  MIN/MAX

  key  again.  The  minimum 

barometric pressure, associated date and time, and the 

MIN

 icon will be displayed.    To reset 

the minimum barometric pressure to the current pressure, press and hold the 

MIN/MAX

 key 

for two seconds. 
 

3.

 

Maximum Remote Temperature (Chanel 1, 2 or 3).   

Press the

 MIN/MAX

 key again. The 

maximum  remote  temperature  (if  you  have  multiple  temperature/humidity  sensors,  the 
channel currently selected on the display), associated date and time, and the 

MAX

 icon will 

be  displayed.    To  reset  the  maximum  remote  temperature  to  the  current  temperature,  press 
and hold the 

MIN/MAX

 key for two seconds. 

 

4.

 

Minimum Remote Temperature (Chanel 1, 2 or 3).   

Press the

 MIN/MAX

 key again. The 

minimum  remote  temperature  (if  you  have  multiple  temperature/humidity  sensors,  the 
channel currently selected on the display), associated date and time, and the 

MAX

 icon will 

be  displayed.    To  reset  the  minimum  remote  temperature  to  the  current  temperature,  press 
and hold the 

MIN/MAX

 key for two seconds. 

 

5.

 

Maximum  Remote  Humidity  (Chanel  1,  2  or  3).   

Press  the

  MIN/MAX

  key  again.  The 

maximum  remote humidity  (if  you  have  multiple  temperature/humidity  sensors, the  channel 
currently  selected  on  the  display),  associated  date  and  time,  and  the 

MAX

  icon  will  be 

displayed.    To reset  the maximum remote humidity  to the current humidity, press and hold 
the 

MIN/MAX

 key for two seconds. 

 

6.

 

Minimum  Remote  Humidity  (Chanel  1,  2  or  3).   

Press  the

  MIN/MAX

  key  again.  The 

minimum  remote  humidity  (if  you  have  multiple  temperature/humidity  sensors,  the  channel 
currently  selected  on  the  display),  associated  date  and  time,  and  the 

MAX

  icon  will  be 

displayed.    To  reset  the  minimum  remote  humidity  to  the  current  humidity,  press  and  hold 
the 

MIN/MAX

 key for two seconds. 

 

7.

 

Press the

 MIN/MAX

 key again to exit the min/max mode. 

4.5 Other Console Features 

The following section describes additional console features. 

4.5.1

 

Backlight 

To  turn  on  backlighting,  press  the 

SNOOZE/LIGHT

  button  on  the  top  of  the  display  console.  The 

backlight will stay on for 5 seconds. 

Содержание WS-1175

Страница 1: ...8 4 3 2 Setting the Time Alarm 8 4 3 3 Cancelling the Alarm 8 4 3 4 Snooze Alarm 8 4 4 Min Max Mode 9 4 5 Other Console Features 9 4 5 1 Backlight 9 4 5 2 Weather Forecasting and Tendency 9 4 5 3 Weat...

Страница 2: ...0 x 1 0 in LCD Dimensions LxW 4 25 x 2 5 1 Thermo hygrometer transmitter WH5 with mounting bracket Dimensions LxWxH 4 5 x 1 25 x 0 5 1 User Manual 2 2 Recommend Tools Philips screwdriver precision Dr...

Страница 3: ...rating properly Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor temperature date and time The outdoor tempe...

Страница 4: ...ry indictor 23 Barometric pressure units of measure 4 Date 14 Indoor comfort index 24 Minimum icon 5 Maximum Icon 15 Indoor temperature 25 Time alarm setting 6 Sensor sensitivity 16 Indoor temperature...

Страница 5: ...1 Connect the remote sensor to the wall bracket it will snap into place 4 Console Operation Note After 30 seconds of inactivity the display will automatically revert to the normal display mode automa...

Страница 6: ...ritory 8 PST Pacific Standard Los Angeles CA USA 7 MST Mountain Standard Denver CO USA 6 CST Central Standard Chicago IL USA 5 EST Eastern Standard New York NY USA 4 AST Atlantic Standard Caracas 3 S...

Страница 7: ...key to adjust the calendar day note that the display format is Month Day Year 11 Change Hour Press the SET key again to set the hour Press the key or key to adjust the hour up or down 12 Change Minut...

Страница 8: ...ions such as Weather com or Wunderground com and set your weather station to match the official reporting station To change the relative pressure when flashing press the key or key to increase or decr...

Страница 9: ...seconds 4 Minimum Remote Temperature Chanel 1 2 or 3 Press the MIN MAX key again The minimum remote temperature if you have multiple temperature humidity sensors the channel currently selected on the...

Страница 10: ...or three consecutive updates 30 minutes the down arrow will be displayed If there is no clear trend in pressure the arrows will not be displayed 4 5 3 Weather Icons The six weather icons are Sunny Par...

Страница 11: ...degC the ice alert icon will be present Figure 6 4 5 8 Indoor Comfort Icon An indoor comfort icon indicates the comfort zone based on indoor humidity as shown in Figure 7 RH 45 RH 45 65 RH 65 Dry Com...

Страница 12: ...sary of Terms Term Definition Absolute Barometric Pressure Relative barometric pressure corrected to sea level To compare pressure conditions from one location to another meteorologists correct pressu...

Страница 13: ...lows 1 Email Support support ambientweather com 2 Live Chat Support www ambientweather com chat html M F 8am to 4pm Arizona Time 3 Technical Support 480 283 1644 M F 8am to 4pm Arizona Time Problem So...

Страница 14: ...r is out of range 20 to 95 Absolute pressure does not agree with official reporting station Make sure you properly calibrate the sensor to an official local weather station reference 4 2 Set Program M...

Страница 15: ...used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manu...

Страница 16: ...urchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by a Ambient LLC The...