Move the remote sensor to a higher location. Move the 
remote sensor to a closer location. 
 
Radio Frequency (RF) Sensors cannot transmit through 
metal barriers (example, aluminum siding) or multiple, 
thick walls. 

Temperature sensor reads too high in the 
day time. 

Make sure the thermo-hygrometer is mounted in a 
shaded area on the north facing wall. Consider the 
following radiation shield if this is not possible: 

http://www.ambientweather.com/amwesrpatean.html

 

 

Indoor and Outdoor Temperature do not 
agree 

Allow up to one hour for the sensors to stabilize due to 
signal filtering. The indoor and outdoor temperature 
sensors should agree within 4 °F (the sensor accuracy is 
± 2 °F) 

Indoor and Outdoor Humidity do not 
agree 

Allow up to one hour for the sensors to stabilize due to 
signal filtering. The indoor and outdoor humidity sensors 
should agree within 10 % (the sensor accuracy is ± 5 %) 

Humidity is reading 20% at low humidity 
or 95% at high humidity 

The humidity sensor is out of range (20 to 95%) 

Absolute pressure does not agree with 
official reporting station 

Make sure you properly calibrate the sensor to an official 
local weather station (reference 4.2 Set (Program) 
Mode4.2 Set (Program) Mode 
 
The barometer is only accurate to ± 0.08 inHg within the 
following relative pressure range: 27.13 to 32.50 inHg, 
which corresponds to an altitude of -2,200 to 2,700 feet.   
At higher altitudes, expect some non-linearity or error. 

The forecast icon is not accurate 

The weather station console must run for several days to 
trend barometric pressure. 
 
The weather forecast is an estimation or generalization of 
weather  changes  in  the  next  24  to  48  hours,  and  varies 
from  location to location. The tendency is simply a tool 
for  projecting  weather  conditions  and  is  never  to  be 
relied upon as an accurate method to predict the weather. 

Display console contrast is weak 

Replace console batteries with a fresh set of batteries. 

 

8.

 

  Accessories 

The  following  software  and  hardware  accessories  are  available  for  this  weather  station  at 

www.AmbientWeather.com

 . 

 

Accessory 

Image 

Description 

Energizer AA Lithium 
Battery (2-pack) - Batteries 
for Long Life and Cold 
Climates

 

 

AA lithium batteries for cold weather 
climates. 

Содержание WS-1175

Страница 1: ...8 4 3 2 Setting the Time Alarm 8 4 3 3 Cancelling the Alarm 8 4 3 4 Snooze Alarm 8 4 4 Min Max Mode 9 4 5 Other Console Features 9 4 5 1 Backlight 9 4 5 2 Weather Forecasting and Tendency 9 4 5 3 Weat...

Страница 2: ...0 x 1 0 in LCD Dimensions LxW 4 25 x 2 5 1 Thermo hygrometer transmitter WH5 with mounting bracket Dimensions LxWxH 4 5 x 1 25 x 0 5 1 User Manual 2 2 Recommend Tools Philips screwdriver precision Dr...

Страница 3: ...rating properly Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor temperature date and time The outdoor tempe...

Страница 4: ...ry indictor 23 Barometric pressure units of measure 4 Date 14 Indoor comfort index 24 Minimum icon 5 Maximum Icon 15 Indoor temperature 25 Time alarm setting 6 Sensor sensitivity 16 Indoor temperature...

Страница 5: ...1 Connect the remote sensor to the wall bracket it will snap into place 4 Console Operation Note After 30 seconds of inactivity the display will automatically revert to the normal display mode automa...

Страница 6: ...ritory 8 PST Pacific Standard Los Angeles CA USA 7 MST Mountain Standard Denver CO USA 6 CST Central Standard Chicago IL USA 5 EST Eastern Standard New York NY USA 4 AST Atlantic Standard Caracas 3 S...

Страница 7: ...key to adjust the calendar day note that the display format is Month Day Year 11 Change Hour Press the SET key again to set the hour Press the key or key to adjust the hour up or down 12 Change Minut...

Страница 8: ...ions such as Weather com or Wunderground com and set your weather station to match the official reporting station To change the relative pressure when flashing press the key or key to increase or decr...

Страница 9: ...seconds 4 Minimum Remote Temperature Chanel 1 2 or 3 Press the MIN MAX key again The minimum remote temperature if you have multiple temperature humidity sensors the channel currently selected on the...

Страница 10: ...or three consecutive updates 30 minutes the down arrow will be displayed If there is no clear trend in pressure the arrows will not be displayed 4 5 3 Weather Icons The six weather icons are Sunny Par...

Страница 11: ...degC the ice alert icon will be present Figure 6 4 5 8 Indoor Comfort Icon An indoor comfort icon indicates the comfort zone based on indoor humidity as shown in Figure 7 RH 45 RH 45 65 RH 65 Dry Com...

Страница 12: ...sary of Terms Term Definition Absolute Barometric Pressure Relative barometric pressure corrected to sea level To compare pressure conditions from one location to another meteorologists correct pressu...

Страница 13: ...lows 1 Email Support support ambientweather com 2 Live Chat Support www ambientweather com chat html M F 8am to 4pm Arizona Time 3 Technical Support 480 283 1644 M F 8am to 4pm Arizona Time Problem So...

Страница 14: ...r is out of range 20 to 95 Absolute pressure does not agree with official reporting station Make sure you properly calibrate the sensor to an official local weather station reference 4 2 Set Program M...

Страница 15: ...used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manu...

Страница 16: ...urchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed by a Ambient LLC The...

Отзывы: