5.4

 

  Barometric Pressure Display and Settings 

5.4.1

 

Barometric Pressure Units of Measure 

In  normal  time  mode,  press  the 

BARO

  button  to  change  barometric  units  of  measure  (hPa  /  inHg  / 

mmHg). 

5.4.2

 

Absolute Pressure vs. Relative Pressure 

Press and hold the 

BARO

 button for 2 seconds to enter barometric mode, and press the 

+/CHANNEL

 

button to switch between the relative and absolute pressure reading. 

5.4.3

 

Relative Pressure Calibration 

Please Reference Section 5.4.3.1 for details on the purpose of calibrating relative pressure, and how 
to calibrate relative pressure in your area. 

 

1.

 

Press and  hold  the 

BARO

  button  for  2  seconds to enter barometric  mode. The icon 

BARO

 

will flash. 
 
Make sure the REL Pressure is showing on the display. If ABS Pressure is showing, switch to 
REL pressure per Section 5.4.2. 
 

2.

 

Press (do not hold) the 

BARO

 button again. The relative pressure will flash. 

 

3.

 

Press the 

+/CHANNEL 

to increase the relative pressure and 

-/MEM

 to decrease the relative 

pressure. 
 

4.

 

Press (do not hold) the 

BARO

 button again to exit the relative pressure calibration mode, or 

wait 60 seconds to time out. 

 
Note: After calibration, the barograph will reset to 0 change (flat line across the graph). 

5.4.3.1

 

Relative vs. Absolute Pressure and Calibration 

The clock displays two different pressures: absolute (measured) and relative (corrected to sea-level). 
 
To  compare  pressure  conditions  from  one  location  to  another,  meteorologists  correct  pressure  to 
sea-level conditions. Because the air pressure decreases as you rise in altitude, the sea-level corrected 
relative  pressure  (the  pressure  your  location  would  be  at  if  located  at  sea-level)  is  generally  higher 
than your measured absolute pressure. 
 
Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but 
the relative pressure is 30.00 inHg (1016 mb). 
 
The  standard  sea-level  pressure  is  29.92  in  Hg  (1013  mb).  This  is  the  average  sea-level  pressure 
around  the  world.    Relative  pressure  measurements  greater  than  29.92  inHg  (1013  mb)  are 
considered high pressure and relative pressure measurements less than 29.92 inHg are considered low 
pressure. 
 
To determine the relative pressure for your location, locate an official reporting station near you (the 
internet  is  the  best  source  for  real  time  barometer  conditions,  such  as  Weather.com  or 
Wunderground.com), and set your weather station to match the official reporting station. 
 

Содержание RC-8401

Страница 1: ... 11 5 2 1 Using the Alarm and Snooze Functions 11 5 3 Projector and Backlight 12 5 3 1 Using the Projector and Backlight 12 5 3 2 Projector Rotation 12 5 3 3 Adjusting Projector Focus 12 5 4 Barometric Pressure Display and Settings 13 5 4 1 Barometric Pressure Units of Measure 13 5 4 2 Absolute Pressure vs Relative Pressure 13 5 4 3 Relative Pressure Calibration 13 5 5 The Forecast Icon 14 5 5 1 P...

Страница 2: ...ty Information 20 1 Introduction Thank you for your purchase of the Ambient Weather RC 8401 ClearView Projection Radio Controlled Alarm Clock with Barometer Forecast Indoor Temperature and Color Changing Outdoor Temperature The following user guide provides step by step instructions for installation operation and troubleshooting To download the latest full sized manual and additional troubleshooti...

Страница 3: ...Version 1 1 Copyright 2016 Ambient LLC All Rights Reserved Page 3 3 Getting Started 3 1Product Features 3 1 1 Display Clock Figure 1 ...

Страница 4: ...ds to enter time set mode In time set mode press to step through the different time and date settings 16 PROJECTION On Off Switch Turns the time and temperature projection on or off 6 ALARM Button In normal time display mode Press TIME button to display ALM1 ALM2 Press ALARM to turn on off ALM1 ALM2 Press to stop the current alarm when the alarm is ringing and turn off the alarm and snooze functio...

Страница 5: ...on 1 Transmitter LED flashes when the remote is transmitting 5 Wall hanger 2 Reset button press reset to restart the transmitter 6 Battery cover 3 Transmitter channel assign the transmitter to 1 2 or 3 default 1 7 Table stand 4 2 x AA batteries Note The WS 8400 supports three wireless channels If you have one sensor leave the transmitter channel at Channel 1 If you have more than one sensor refer ...

Страница 6: ...arch for the time signal at 2 00 8 00 14 00 2pm and 20 00 8pm Note The clock will always display the color green when the clock is searching for the radio controlled signal The mono color green is best for avoiding wireless interference from the display Note If no display is present after powering up the clock press the reset button on the back of the clock with an open ended paper clip or sharp t...

Страница 7: ...d transmission barriers such as walls In general wireless signals will not penetrate solid metal and earth down a hill for example The following is a table of reception loss vs the transmission medium Each wall or obstruction decreases the transmission range by the factor shown below Medium RF Signal Strength Reduction Glass untreated 5 15 Plastics 10 15 Wood 10 40 Brick 10 40 Concrete 40 80 Metal...

Страница 8: ...perature Alert 3 Weather Forecast 12 Min Max indicator 4 History Mode indicator 13 Wireless temperature channels 1 2 or 3 5 Rel Abs Pressure 14 Indoor temperature 6 Barometer indictor 15 Month and Day 7 Barometer reading 16 Day of Week 8 Barometer units of measure inHg hPa mmHg 17 Radio Controlled Time Reception Icon 9 Wireless signal strength indicator Figure 4 4 2 Alarm Time Display Mode ...

Страница 9: ... All Rights Reserved Page 9 No Description No Description 1 Alarm Time 3 Alarm 2 On 2 Alarm 1 On Figure 5 5 Settings 5 1Time Date and Language Settings While in normal time mode perform the following operations to set date time and language ...

Страница 10: ...DE German ES Spanish and IT Italian TIME Time Zone Press CHANNEL to change between auto most of USA and Canada and OFF Arizona and Hawaii TIME Exit Time and Date Settings TIME 2 seconds means press and hold the TIME button for two seconds TIME means press but do not hold the TIME button Figure 6 5 1 1 Hour Offset The clock allows you to set four time zones Pacific PST Mountain MST Central MST and ...

Страница 11: ...ARM 2 seconds Enter Alarm Settings Alarm Hour Press CHANNEL to increase MEM to decrease ALARM Alarm Minute Press CHANNEL to increase MEM to decrease ALARM Exit Alarm Settings ALARM 2 seconds means press and hold the ALARM button for two seconds ALARM means press but do not hold the ALARM button Figure 7 5 2 1 Using the Alarm and Snooze Functions 1 Set the alarm time as described in Section 5 2 Whi...

Страница 12: ...e Slide the PROJECTION ON OFF switch to OFF position and the projection will be off all of the time unless you press the SNOOZE LIGHT button as described in the previous section Slide the LIGHT ON OFF switch to ON position and the backlight will be on all the time Slide the LIGHT ON OFF switch to OFF position and the backlight will be off all of the time unless you press the SNOOZE LIGHT button as...

Страница 13: ...mode or wait 60 seconds to time out Note After calibration the barograph will reset to 0 change flat line across the graph 5 4 3 1 Relative vs Absolute Pressure and Calibration The clock displays two different pressures absolute measured and relative corrected to sea level To compare pressure conditions from one location to another meteorologists correct pressure to sea level conditions Because th...

Страница 14: ...me they were reset Command Mode Settings MEM Displays Outdoor Maximum Temperature and the associated date and time Press and hold MEM for two seconds to reset the maximum outdoor temperature to the current value MEM Displays Outdoor Minimum Temperature and the associated date and time Press and hold MEM for two seconds to reset the minimum outdoor temperature to the current value MEM Displays Indo...

Страница 15: ...the possible colors Once the preferred color is displayed press the LOOP ON OFF button again to stop the color cycling 5 8 2 Outdoor Temperature Color Place the MANUAL TEMP COLOR slide switch in the temp position The display color will automatically change based on the color chart below Temperature Range F Color 1 0 White 2 0 10 Violet 3 10 20 Dark Blue 4 20 30 Light Blue 5 30 40 Dark Aqua 6 40 50...

Страница 16: ...de the L H switch low high 5 12 Wireless Sensor Display No Description No Description 1 Low Battery Indicator 4 Temperature Channel Number 2 Temperature 5 Channel Number default 1 and Reception Icon on when searching flashes when updates 3 Temperature Units of Measure F or C Figure 13 5 13 Wireless Sensor Low Battery Indictor When the battery is full no battery icon will be displayed When the batt...

Страница 17: ...y will show dashes Wait several minutes for resynchronization To reset the console disconnect from AC power and remove the batteries for 10 seconds then reinsert the batteries and reconnect AC power Alternately you can press the RESET button on the back of the console The sensor display will show dashes Wait several minutes for resynchronization 5 16 Adding Multiple Wireless Sensors If you introdu...

Страница 18: ... 1100mb 25 C 1hPa 0 01inHg 0 1mmHg 6 2 Power Consumption Display 3 x AAAlkaline batteries recommended Display DC 4 5V 300mA adaptor Wireless Transmitter 2 x AA Alkaline batteries recommended Lithium e2 Energizer for cold weather 7 Troubleshooting Guide If your question is not answered here you can contact us as follows 1 Email Support support ambientweather com 2 Technical Support 480 346 3380 M F...

Страница 19: ...oser location Radio Frequency RF Sensors cannot transmit through metal barriers example aluminum siding or multiple thick walls The clock does not respond to commands Press the reset button on the back of the clock with an open ended paper clip or sharp tool The projection is fuzzy Adjust the focus setting The clock is dim when running on batteries only Press the snooze light button or connect to ...

Страница 20: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Страница 21: ...er s manual 3 damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient LLC authorized service center 4 units used for other than home use 5 applications and uses that this product was not intended 6 the products inability to receive a signal due to any source of interference or metal obstructions and 7 extreme acts of nature such as lightning stri...