Set Your Ideal Heating Programme

With 3 diff erent options available, choose 
the schedule which best suits your lifestyle. 
Whether that is all 7 days the same (7day), 5 
days and the weekend (5/2), or just 6 days and 
just 1 separate day (6/1).

 

Having initiated the advanced 

  settings, tap the        button 
  until you reach (6PRG) to set 
  your programme. 

 

Use the       and       buttons to set 

    which programme you require.

  

The image above indicates a 7 day schedule.    

    A 5/2 schedule would only show digits 1-5             
    & a 6/1 schedule would only show digits 1-6.

 

Use the       button to switch off  and save 

  your settings.

Alternatively, you can switch off  the heating 
schedule altogether - simply choose the option 
Programme off  when setting.

Create The Perfect Heating Schedule

Please note down the scheduled times prior to beginning 
programming. 
By default, your Amber-Touch will be set to a 5/2 schedule. 
To personalise this schedule:  Enter schedule mode by pressing 
the        button

5 Day Schedule

  You will see one of the 6 period symbols and the        symbol
  Hold the        button until the fi rst period is displayed on 
  the screen
  You can then set the start time for period 1 using the      and 
  buttons
  Save your start time by pressing the        button, and now 
  use the      and      buttons to set the desired temperature and 
  press the        button
  Repeat steps for 3 & 4 to set all 6 periods

Weekend Schedule

  After completing the 5 day schedule, press the        button 
  for weekend heating
  The time you select will apply for both Sat and Sun
  Save your start time by pressing the        button, and use 
  the      and      buttons to set the desired temperature
  Press the        button to advance to period 2
  Set the desired start time and temperature
  Finally, press the       button to save your 7 day 
  heating schedule

Amber-Touch

Complete Guide

Up

Button

Down

Button

Menu

Button

Clock

Button

Power

Button

Sensor

Before programming your Amber-Touch 
please ensure you read through all these 
settings carefully.

Manual Control

If required you may choose to access manual 
control of your Amber-Touch. You can easily 
switch between the manual mode      and your 
custom schedule by tapping the        button
When in manual mode, you will see the 
manual control mode icon     , and can 
manually set a desired temperature for your 
room by using the       and       buttons.
The      symbol will appear when the desired 
temperature is set above the ambient room 
temperature.

Frost Protection

An active frost protection feature will ensure 
your substrate never falls below 10°C. Helping 
to reduce the heat up times and protecting the 
fl oor fi nish from potential damage.

 

Having initiated the advanced settings, tap 

  the        button continuously until you see 
  the frost protection mode (5LrP)

 

Using the       and       buttons, simply set 

  this to ‘ON’ to activate.

 

Use the       button to switch off  and save 

  your settings.

Maximum Floor Temperature

  

Having initiated the advanced settings, tap    

   the       button continuously until you see the                         
   maximum fl oor temperature mode (3Lit).

  

Use       and        buttons to set required                

   temperature

  

Press the       button to save

1

2

3

5

4

1

2
3

5

4

6

Sensor Mode

Having initiated the advanced settings, tap the          
        button to switch to Sensor Mode (2SEN) and 
set to OUT by using the       and       buttons
There are 3 sensor modes available to choose 
from, Air Sensor Only (IN), Floor Sensor Only (OUT)
and Air Sensor with Floor Limit (ALL), you can 
scroll through these using the       and       buttons.
Use the       button to switch off  and save your 
settings.

We would recommend Floor Sensor Only (OUT) for wetrooms 
where the thermostat is located outside the heated area or 
where the heating is only required for fl oor warming.
Air Sensor with Floor Limit (ALL) is used where the thermostat is 
located within the heated room and the underfl oor heating is the 
primary heat source.
DO NOT use Air Sensor Only (IN) with underfl oor heating.

Time & Date Setup

 

With the unit on, simply hold the         button 

  until the minutes begin to fl ash (5 seconds)

 

Set the correct time by using the       and 

  buttons, using the         button to switch from 
  minutes to hours and again to edit the day

 

Use the       and       buttons to select the 

  correct day: 1 = Monday, 7 = Sunday

 

Tap the         button to complete the process

Initiate Advanced Settings

Advanced settings must be confi gured before 
programming, to initiate:
  Switch off  the unit by tapping the       button
  Simultaneously hold the       and         buttons 
  until 1ADJ shows on the screen

1

2

Air Sensor

(IN)

Floor Sensor 

(OUT)

Air Sensor with 

Floor Limit (ALL)

1

2

3

4

5

6

7

Up

Down

Power

Manual Control 

Mode

Programme 

Mode Indicator

Menu

Heating On

Clock

Period 1

Period 2

Period 3

Period 4

Period 5

Period 6

Screen

Lock

For technical information contact:

[email protected]

0800 056 0494

Содержание Amber-Touch

Страница 1: ...Amber Touch Complete Guide Up Button Down Button Menu Button Clock Button Power Button Sensor...

Страница 2: ...carefully DO NOT use Air Sensor Only IN with underfloor heating Up Down Power Manual Control Mode Programme Mode Indicator Menu Heating On Clock Period 1 Period 2 Period 3 Period 4 Period 5 Period 6...

Страница 3: ...switch from minutes to hours and again to edit the day Use the and buttons to select the correct day 1 Monday 7 Sunday Tap the button to complete the process Initiate Advanced Settings Advanced settin...

Страница 4: ...he and buttons Use the button to switch off and save your settings We would recommend Floor Sensor Only OUT for wetrooms where the thermostat is located outside the heated area or where the heating is...

Страница 5: ...d the advanced settings tap the button until you reach 6PRG to set your programme Use the and buttons to set which programme you require The image above indicates a 7 day schedule A 5 2 schedule would...

Страница 6: ...start time for period 1 using the and buttons Save your start time by pressing the button and now use the and buttons to set the desired temperature and press the button Repeat steps for 3 4 to set al...

Страница 7: ...between the manual mode and your custom schedule by tapping the button When in manual mode you will see the manual control mode icon and can manually set a desired temperature for your room by using t...

Страница 8: ...dvanced settings tap the button continuously until you see the frost protection mode 5LrP Using the and buttons simply set this to ON to activate Use the button to switch off and save your settings Ma...

Страница 9: ...external floor sensor probe Contact your electrician who can isolate the electricity supply and check the sensor is connected and working correctly Screen Lock In some situations where your Amber Touc...

Страница 10: ...gs tap the menu button continuously until you see AFAC 2 Hold the button until is displayed on the screen 3 Press the button and switch off at the mains to complete factory reset Please note the time...

Страница 11: ...t in sensor OUT floor sensor ALL both sensors floor sensor is the limit sensor 3 LIT Max floor temperature 35 C Adjust limitation value Limitation range 5 C 35 C 4 DIF Switching differential 1 Adjust...

Страница 12: ...7 day mode 7 RLE Output N A Not Used 8 DLY Output delay 0 Change the delay time 9 HIT Max temperature setting 50 C Max Limitation temperature setpoint 50 C 10 AFAC Reset to factory settings N A Progr...

Страница 13: ...Dimensions 86mm 13mm 30mm 98mm...

Страница 14: ...Installation Guide STEP 1 Release the front cover by inserting screwdriver into the hole on the underside of the front plate...

Страница 15: ...STEP 2 Take the backing plate apart according to diagram STEP 3 Install the backing plate on to the electrical connection box with screws before any wiring takes place 16...

Страница 16: ...STEP 4 Ensure all wiring is undertaken by a qualified electrician STEP 5 Install the housing cover and lock external frame as per diagrams 1 2 3 4 5 6 7 16A L1 N1 N L Sensor Max load 16A 3600W...