background image

 

 

Status LED indications 

Behaviour 

Meaning 

Blinking every second  

Normal mode  

Blinking every two seconds  

Sleep mode  

Blinking fast for a short time  

Modem activity  

Off  

Device is not working or Device is in boot mode  

  Characteristics

 

      Basic characteristics 

 

Module  

Name  

ACT 400-m 

Technology  

LTE CAT M1/NB-IoT/GSM/GPRS/GNSS/BLUETOOTH 

 

GNSS  

GNSS  

GPS, GLONASS, GALILEO, BEIDOU, QZSS, AGPS 

Receiver  

Tracking: 33 

Tracking sensitivity  

-165 dBM  

Accuracy  

< 3 m  

Hot start  

< 1 s  

Warm start  

< 25 s  

Cold start  

< 35 s  

 

Cellular  

Technology 

LTE CAT M1/NB-IoT/GSM 

2G bands 

BG95: B2/B3/B5/B8 
BG96: B2/B3/B5/B8 

4G bands  

BG95: LTE-FDD (CAT M1): 
B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/
B28/B66/B85 
LTE-FDD (CAT NB2): 
B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B28/B66/
B71/B85 GSM: 850/900/1800/1900 
BG96: LTE FDD:

 

B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B28 
LTE TDD: B39 (for CAT M1 only) 

Data transfer 

BG95: 

 

LTE: Max. 588Kbps (DL)/Max.1119Kbps (UL) 

GPRS: Max. 107Kbps (DL)/Max. 85.6Kbps (UL) 
BG96: 
LTE: Max. 375Kbps (DL)/Max.375Kbps (UL) 
GPRS: Max. 107Kbps (DL)/Max. 85.6Kbps (UL) 

Transmit power 

Class 4 for GSM850/900:    23±2dBm 
Class 1 for GSM1800/1900:   20±2dBm 
Class 3 for LTE-TDD:    23±2.7dBm 
Class 3 for LTE-FDD:   23±2.7dBm 

Data support 

SMS (text/data) 

 

Power  

Input voltage range  

10-30 V DC with overvoltage protection  

Back-up battery  

170 mAh Li-Ion battery 3.7 V (0.63 Wh)  

Internal fuse  

3 A, 125 V  

Power consumption  

At 12V < 3 mA (Ultra Deep Sleep)  
At 12V < 5 mA (Deep Sleep) 
At 12V < 11 mA (Online Deep Sleep) 

Содержание Amber Govern T400-m

Страница 1: ......

Страница 2: ...t channel 3 4 DIN 2 N AIN 1 Digital input channel 2 Negative input ground sense Analog input channel 1 Input range 0 30 VDC 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 1...

Страница 3: ...Wiring scheme ACT 400 m Wiring scheme Set up your device How to insert Micro SIM card and connect the battery Cover removal Micro SIM card insert Battery connection Attaching cover back...

Страница 4: ...de power might be still available on the power wires Depending on the car model this may happen in 5 to 30 minutes period 2 When the module is connected measure the voltage again to make sure it did n...

Страница 5: ...4 B5 B8 B12 B13 B18 B19 B20 B25 B26 B27 B28 B66 B85 LTE FDD CAT NB2 B1 B2 B3 B4 B5 B8 B12 B13 B18 B19 B20 B25 B28 B66 B71 B85 GSM 850 900 1800 1900 BG96 LTE FDD B1 B2 B3 B4 B5 B8 B12 B13 B18 B19 B20 B...

Страница 6: ...mperature with battery 20 C to 45 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperature 20 C to 60 C Features...

Страница 7: ...voltage V Input Voltage threshold DIN1 7 5 V Input Voltage threshold DIN2 2 5 V Input Voltage threshold DIN3 2 5 V Analog Input Input voltage Recommended Operating Conditions Range 1 0 10 V Input res...

Страница 8: ...x6 connector wires to the vehicle the appropriate jumpers of the vehicle power supply should be disconnected Before unmounting the device from the vehicle the 2x6 connector must be disconnected The de...

Страница 9: ...eral household waste Hereby Amber declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization European Directive 2014 53 EU RED 17...

Страница 10: ...excluded also excluded from this limited warranty are any and all incidental or consequential damages including but not limited to loss of use or revenue loss of time inconvenience or any other econom...

Отзывы: