6

www.ambaproducts.com

DIGITAL HEAT CONTROLLER (DHC) INSTALLATION

INSTRUCTIONS

A - Power Source Cable

B - DHC Supply Cable

C - DHC Output cable

D - Towel Warmer cable

E - Ground faston

POWER

REGULATOR

1

 Connect T1 (A)-T2(B)-T3(D) to faston T(E) 

2

 Connect L 1 (A)-L2(B)

3

 Connect N 1 (A)-N2(8)

4

 Connect N3(0)-N4(C)

5

 Connect L3(0)-L4(C)

Level Settings:

1 — Minimum Heat
9 — Maximum Heat

Can be wired in conjunction 
with a programmable timer. 

(CONSULT ELECTRICIAN)

STEP 1

STEP 2

Содержание Quadro Q2052

Страница 1: ... SKU Width HEIGHT Power Amps BTU Q2016 20 1 2 16 3 4 92 watts 0 8 314 Q2033 20 1 2 33 1 4 172 watts 1 5 586 Q2042 20 1 2 42 5 16 232 watts 2 0 791 Q2052 20 1 2 54 1 2 296 watts 2 6 1009 Q2833 28 3 8 33 1 4 232 watts 2 0 791 Q2842 28 3 8 42 3 8 296 watts 2 6 1009 COMPONENTS 1 2 3 4 5 6 8 7 1 Plastic Anchor 2 Threaded Wall Support 3 Anchor Screw 4 Threaded Long Tube 5 Cover 6 Setscrew 7 Fixing Screw...

Страница 2: ...ired The unit has to be connected to a power supply circuit equipped with an omni polar disconnection electrical system with a distance among contacts of 1 8 Caution high temperature risk of fire keep electrical cords drapery furnishings other combustibles away from the front of the heater Bad smells may be caused by residues inside the heater or by the inner plastic parts as unit operates with no...

Страница 3: ...during normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards For residue buildup do not use extreme pressure on the surface to avoid scratches damages to the heater It is also possible to use a solvent use caution make sure to read the technical forms and norms for it s use In case of uncertainty do ...

Страница 4: ...uctural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support point 2 on the hole and fasten it with the anchor bolt screw repeat this procedure also for the other points marked on the wall Fixing Screw Bushing BACK SIDE OF TOWEL WARMER Laythe bushing point 6 on the holes of the towel warmer And fasten it with the fix...

Страница 5: ...or use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consult the wiring diagram Do not insert foreign bodies inside the digital heat controller in order to avoid electric shocks or damages to it Do not use the digital heat controller close to combustibles pa...

Страница 6: ...HC Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Settings 1 Minimum Heat 9 Maximum Heat Can be wired in conjunction with a programmable timer CONSULT ELECTRICIAN STEP 1 STEP 2 ...

Страница 7: ...t the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical bridge 1 2 2 1 Fix the stainless steel wall plate with the provided screws Power source cable Fastening Connections Step 2 Towel warmer cable COMPONENTS WALL PLATE FASTENING CONNECTIONS SWITCH INSTALL...

Отзывы: