![Amazone UF 1201 Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/amazone/uf-1201/uf-1201_operating-manual_2919803184.webp)
Cleaning, maintenance and repairs
13.5.5
Fluid filter
•
Profi-folding only:
Hydraulic fluid filter (Fig. 145/1) with contamina-
tion indicator (Fig. 145/2).
•
Green
Filter fully functional
•
Red
Replace filter
To remove the filter, twist off the filter cover and
remove the filter.
WARNING
Beforehand, depressurise the hy-
draulic system.
Otherwise there is a risk of injury from
hydraulic fluid escaping at high pres-
sure.
After replacing the filter, press the contamination
indicator back into place.
→
Green ring again visible.
Fig. 137
13.5.6
Cleaning the solenoid valves
•
hydraulic block for Profi-folding
To eliminate impurities from the solenoid valves,
they must be flushed through. This may be nec-
essary if deposit prevent the slider fully opening
or closing.
1. Unscrew the magnetic cap (Fig. 146/1)
abschrauben.
2. Remove the solenoid (Fig. 146/2) abneh-
men.
3. Unscrew the valve rod (Fig. 146/3) with
valve seats and clean with compressed air
or hydraulic fluid
Fig. 138
CAUTION
Beforehand, depressurise the hy-
draulic system.
Otherwise there is a risk of injury from
hydraulic fluid escaping at high pres-
sure.
184
UF BAG0012.11 04.19
Содержание UF 1201
Страница 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Страница 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Страница 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Страница 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Страница 219: ...Spray table UF BAG0012 11 04 19 219 ...
Страница 220: ......