Construction and function of the sprayer boom
DUS pressure circulating system (optional)
Part-width section control: When using drag hoses, the pressure cir-
culating system should usually be switched off.
The pressure circulating system
•
enables the constant circulation of liquid in
the spray line when the pressure circulating
system is switched on. To do so, a suction
port hose (1) is assigned to each part-width
section.
•
can be operated using spray liquid or flush-
ing water, as desired.
•
reduces the undiluted residue for all spray
lines to 2 l.
The constant circulation of liquid
•
enables production of a uniform spray pat-
tern right from the start, because spray liq-
uid is available at every spray nozzle im-
mediately after the sprayer boom is
switched on, with no delay.
•
prevents clogging of the spray line.
Line filter for spray lines (optional)
The line filter (1) is
•
installed in the spray lines in each part-
width section (part-width section control).
•
installed in the spray lines on the left and
right (single nozzle control)
•
an additional measure to prevent contami-
nation of the spraying nozzles.
Overview of the filter inserts
•
Filter insert with 50 mesh/inch (blue)
•
Filter insert with 80 mesh/inch (grey)
•
Filter insert with 100 mesh/inch (red)
104
UF BAG0012.11 04.19
Содержание UF 1201
Страница 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Страница 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Страница 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Страница 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Страница 219: ...Spray table UF BAG0012 11 04 19 219 ...
Страница 220: ......