![Amazone Catros 4003-2TS Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/amazone/catros-4003-2ts/catros-4003-2ts_original-operating-manual_2919720078.webp)
8.3 Grease emerging on the pump for the central lubrication
Grease nipple blocked
Depending on the equipment, the central lubrication
system consists of several distributors that are
connected to each other.
1.
Pump in the grease through the grease nipple
1
on the last distributor as seen from the pump.
2.
Check for grease emerging from the lubrication
points belonging to the distributor.
3.
If no grease emerges from a lubrication point,
remove the grease nipple from the faulty
lubrication point and clean it.
4.
Clean faulty lubrication points.
5.
Reinstall the grease nipple on the faulty
lubrication point.
6.
Pump in grease again through the grease nipple
1
.
7.
Check the cleaned lubrication points for emerging
grease.
8.
Repeat the procedure on all of the distributors.
-MAX-
-MIN-
1
CMS-I-00004521
When all of the faulty lubrication points have been
cleaned, the central lubrication system can be tested
over a longer period of time as follows:
9.
Set the blue rotary knob on the pump at "3" and
the red rotary knob at "9".
10. Supply the central lubrication system with power
for 12 hours.
11.
If grease emerges on the pump after 12 hours,
repeat the fault repair.
-MAX-
-MIN-
9
3
CMS-I-00004520
CMS-T-00006312-A.1
8 | Eliminating faults
MG6828-EN-II | N.1 | 13.08.2021