Settings
A BAH0040-9 01.19
31
6. Stop after exactly 100 m.
The display (Fig. 27) shows the calibration
value
(e.g. 1005 pul./100 m).
7. Enter the calculated calibration value in the
table (Fig. 61, Seite 65) (recommendation).
8. Press
.
Save the calibration value (pul./100 m).
Fig. 27
The calibration value (imp./100 m) must not be less than 250.
Otherwise the control terminal will not work properly.
You can enter the determined calibration value in the table (Fig. 61).
6.7.2
Displaying / editing the stored calibration value (pulses per 100 m)
1. Bring implement to a standstill.
2. Press
.
Display:
The stored calibration value (pul./100 m),
e.g. 1053 (Fig. 28).
3. Alter the stored calibration value
(imp./100 m)
by using the
and
buttons.
4. Press
.
Save the selected value.
Fig. 28