EN
10
»
If an unusually long air hose is required,
(26�2 ft / over 8 meters), the air pressure
or the hose inside diameter may need to
be increased�
»
The air hose must be rated at least 150%
of the maximum operating pressure of
the tool�
»
A typical air line layout is shown in
chapter 4�1� If an automatic lubricator
is used, it will keep the tool in good
condition, but should be regularly
checked and topped up with oil�
»
SAE 10
oil should be used and the
lubricator adjusted to approximately
2 drops per minute�
»
Do not exceed the maximum pressure
for the tool of 90 PSI (6�2 bar)� Higher
pressures and contaminated air will
shorten the life of the tool due to faster
wear and is a possible safety hazard�
»
Change filters on the air system on a
regular basis�
4.1 Air line layout diagram
Air Tool
Hose
Lubricator
Regulator
Filter
Shut-off Valve
Drain
Compressor
Drain
Air Dryer
Auto drain