21
EN
• If
OL
appears on the display (F), remove and
discharge the capacitor.
• The stabilized value on the display (F) is read as
the actual reading.
NOTICE
For very large values of capacitance
measurement, it can take several minutes before
the final reading stabilizes.
NOTICE
When measuring electrolytic
capacitors, follow the polarity (+, –) of its leads to
have a precise measurement.
Frequency/duty cycle measurement
• Insert the black connector lead (P) into the
negative
COM
(black) terminal (I) and the red
connector lead (P) into the positive
V
(red)
terminal (J).
• Set the function switch (L) to the
/Hz/%
position.
• Press the
MODE
button (H) to shift to
measuring the frequency
Hz
(Hertz).
• Connect the test probes (P) across the circuit
or component being measured.
• The stabilized value on the display (F) is read as
the actual reading.