background image

 

25 

TROUBLE SHOOTING

 

 

PROBLEM   

POSSIBLE CAUSE 

SOLUTION 

Dim or no flame 

Flame LED

s are burnt out 

Inspect the LED

s and replace them if 

necessary. 

Ember  bed  is  not 
glowing or dimming 

Ember LED

s are burnt out 

Inspect  the  ember  bed  LED

s  and 

replace them if necessary. 

Appliance  has  overheated  and 
safety  device  has  caused  the 
thermal switch to disconnect 

Turn  off  the  main  switch,  allow 
appliance to cool for 10 minutes, then 
turn it on. 

House  circuit  breaker  has 
tripped 

Reset house circuit breaker. 

Appliance  turns  off  and 
will not turn on 

Appliance

s fuse has blown 

Replace the fuse. 

Appliance is not plugged into an 
electrical outlet 

Check plug and plug in. 

Appliance  has  overheated  and 
safety  device  has  caused  the 
thermal switch to disconnect 

Turn  off  the  main  switch,  allow 
appliance to cool for 10 minutes, then 
turn it on. 

Appliance will not come 
on  when  switch  is 
flipped to ON 

Circuit board is burnt out 

Inspect  the  circuit  board  and  replace 
it if necessary. 

No warm air coming out 
of appliance 

Heater is burnt out 

Inspect  the  burner  and  heater 
assembly and replace it if necessary. 

Flame sputters 
 

Flame motor is defective. 

Call a qualified service technician and 
replace flame motor. 

Remote  Control  does 
not work. 

Low batteries. 
Unit switch in 

O

 position. 

Replace  AAA  batteries  in  remote 
control.   
Turn the switch in 

I

 position. 

Flame is fixed. 

Wiring  may  be  loose  or  the 
flame motor may be defective. 

 

 

 

 

 

 

Содержание BI-40-DEEP

Страница 1: ...ormation in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...m your Amantii product IMPORTANT INSTRUCTIONS 3 UNPACKING AND TESTING APPLIANCE 4 GROUNDING APPLIANCE 4 LOCATING THE FIREPLACE 4 BI 40 DEEP 5 BI 50 DEEP 6 BI 60 DEEP 7 BI 72 DEEP 8 BI 88 DEEP 9 INSTALLATION 14 SAFETY DRILL SCREW AREA 10 FOR BATHROOM USE 12 HARD WIRE INSTALLATION 11 PANORAMA COVER INSTALLATION 18 MEDIA OPTIONS 19 OPERATION 20 INSTALLING WALL THERMOSTAT 22 REPLACEMENT PARTS 23 EXPLO...

Страница 3: ... or exhaust opening as this may cause an electric shock fire or damage to the heater 9 To prevent a possible fire do not block air intakes in any manner 10 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 11 Use this heater only as described in this manual Any other use not recommended by the manufacturer may c...

Страница 4: ...y grounded outlet box The adapter should not be used if a three slot grounded receptacle is available To disconnect appliance turn controls to off then remove plug from outlet LOCATING THE FIREPLACE Plan where to locate and frame the fireplace This will save time and money later when you install the fireplace Before installation consider the following 1 Where the fireplace is located must allow fo...

Страница 5: ... 40 25 or 101 6 cm 63 5cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes use the...

Страница 6: ... 25 or 127 cm 63 5 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes use the cur...

Страница 7: ...e 60 25 or 152 4 cm 63 5 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes use t...

Страница 8: ...73 1 2 25 or 186 7 cm 63 5 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes use...

Страница 9: ...89 1 4 25 or 226 7 cm 63 5 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes use...

Страница 10: ...If it is necessary to hard wire this appliance a qualified electrician must remove the cord connection and wire the appliance directly to the household wiring This appliance must be electrically connected and grounded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICA...

Страница 11: ...d it must be readily accessible To prevent electric shock please be aware that this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit This must be installed away from shows tubs etc Never locate fireplace where it may fall into a bathtub or other water container All wiring connections to line power shall be in accordance with local ...

Страница 12: ...from direct water impingement In addition to maintaining the listed mantel and combustibles clearances a rain protection overhang factor of 1 2 shall be constructed to the front and to each side of the installed appliance See illustration below All wiring connections to line power shall be in accordance with local building code requirements Inquires about local codes and regulations must be done p...

Страница 13: ...e used as an alternate finish option Note The optional trim can be pulled out directly from the unit It will need two people to do it The rough wall opening size of the fireplace W D H BI 40 DEEP 40 12 25 BI 50 DEEP 50 12 25 BI 60 DEEP 60 12 25 BI 72 DEEP 73 1 2 12 25 BI 88 DEEP 89 1 4 12 25 1 Take out the unit from the box Please do the pre test before you install the fireplace Pull out the optio...

Страница 14: ...2 Remove the framing plates from the unit framing plate 3 Re fix the framing plates to the unit as the picture shows framing plate 14 ...

Страница 15: ...4 Bend up the framing plates 5 Put the unit into the opening 15 ...

Страница 16: ...ll studs 7 After checking that the fireplace operates properly cover the glass panel with protective plastic bag and install plywood or drywall Fireplace 16 framing plate NOTE In order to use the supplied trim kit the thickness of the desired wall finish can not exceed 1 inch ...

Страница 17: ...8 Decorate the plywood or drywall with glazed tile wallpaper etc Fireplace 9 Put back the trim that you ve removed from the unit at STEP 1 trim 17 ...

Страница 18: ...les will need to be attached to the cover with the provided hardware as shown in fig 1 First place a plate washer and then a spring washer on the screw as shown in fig 2 Affix the handles to the front of the cover using the prepared screws Fig 3 Insert the assembled cover onto the unit as shown in Figs 4 and 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 ...

Страница 19: ...edia Log Installation 1 Take off the front clear glass There is a bracket which hold the front glass It is show as below Unscrew the screw and take off the bracket Turn around and insert to the gap It can hook the glass and pull out the glass 2 Installing the fire glass media Pour the fire glass media into the tray as shown below Feel free to use any combination of fire glass media that you find m...

Страница 20: ...ve 25 77 the heater will be turned off and the cycle will continue The LED indicator will be PURPLE in colour under this mode 4 Flame effect Press the button marked to adjust the flame brightness The flame brightness will cycle through Low Medium High OFF 5 Mood light effect Press the button marked to change the mood light colour NOTE If operated at the Low heat setting the fireplace will not prov...

Страница 21: ...place flame and tray light ON OFF It has functions of setting memory DISPLAY BLUE button Adjust the blue color brightness of flame and tray DISPLAY YELLOW button Adjust the yellow color brightness of flame and tray DISPLAY ORANGE button Adjust the orange color brightness of flame and tray MOOD LIGHT ON OFF button Switching the mood light ON OFF ADJUST button Switching the color of the mood light F...

Страница 22: ...G 24 VAC Install Wall Thermostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Pull the wire out and cut the inside thermostat Connect the wires to the wall thermostat as shown below Follow instructions provided with wall switch kit ...

Страница 23: ...ASSEMBLY 2 8 601136B 601136B 601136B 601137B 601137B LED STRIP 9 10203015 10203015 10203015 10203015 10203015 ADJUSTABLE FOOT 4 10 FLAME EFFECT GLASS CLEAR GLASS WITH BLACK PLASTIC 1 11 3057012 3057012 3057012 3057012 3057012 GLASS BRACKET LH 1 12 3057013 3057013 3057013 3057013 3057013 GLASS BRACKET RH 1 13 10702155 10702152 10702156 10702153 10702157 BOTTOM GLASS 1 14 3109017 357017 3110017 3580...

Страница 24: ...24 EXPLODED VIEW ...

Страница 25: ... plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 minutes then turn it on Appliance will not come on when switch is flipped to ON Circuit board is burnt out Inspect the circuit board and replace it if necessary No warm air coming out of appliance He...

Страница 26: ...26 SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES ...

Страница 27: ...27 ...

Отзывы: