5
THIS APPLIANCE MUST BE GROUNDED.
If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk electric shock. This machine is equipped
with a cord having an equipment grounding conductor
and grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the
appliance - if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit,
and has a grounding plug that looks like the plug
illustrated in sketch A.
*This applies only
to North America.
Most other countries
use 230V circuit.
WARNING:
UV-C emitted from this product. Avoid
eye and skin exposure to unshielded product. Follow
installation instructions and user manual.
WARNING:
Do not operate device without filter and
cover securely attached. Operating in this manner could
expose those nearby to UV-C radiation UV-C radiation
can cause severe burns of the skin and eye injuries,
(photokeratitis).
WARNING:
This device uses UV-C bulbs
or lamps that contain Mercury. The U.S.
Environmental Association, (EPA),
classifies Mercury as hazardous waste.
The bulbs cannot be disposed as trash
or rubbish. They must be recycled.
For more information, see the following:
US:
http://www.lamprecycle.org/
Canada:
https://www.canada.ca/en/environment-
climate-change/campaigns/diverting-mercury-
light-bulbs.html
Australia:
https://recyclingnearyou.com.au/
For all other regions, please consult your local recycling
authority.
CAUTION:
Fan must be operating prior to supplying
power to UV-C bulbs. Supplying power to bulbs without
fan operating will cause bulbs to overheat and fail.
Grounding Instructions
GROUNDING
PIN
GROUNDING
OUTLET
GROUNDED
OUTLET BOX
Description
250AP115
250AP115C
250AP230
Voltage (V)
115
115
230
Current (A)
3.5
3.5
1.8
Power (W)
403
403
414
AIR FLOW
High Speed
2700 CFM
2700 CFM
2700 CFM
4587 CMH
4587 CMH
4587 CMH
Low Speed
1785 CFM
1785 CFM
1785 CFM
3033 CMH
3033 CMH
3033 CMH
Weight
57 lbs (25,9 kg)
57 lbs (25,9 kg)
55 lbs (24,9 kg)
Length
24” (61 cm)
24” (61 cm)
24” (61 cm)
Width
22.5” (57 cm)
22.5” (57 cm)
22.5” (57 cm)
Height
34” (86 cm)
34” (86 cm)
34” (86 cm)
SOUND LEVEL
High Speed
68.9 dBa
68.9 dBa
68.9 dBA
Low Speed
61.9 dBa
61.9 dBa
61.9 dBA
Cord
20 ft x 16/3 SJTW
20 ft x 16/3 SJTW
60 cm x 3,3 mm
2
| C20 Connection
Fan Blade
6 x 16.5” (42 cm)
6 x 16.5” (42 cm)
6 x 16.5” (42 cm)
Circuit Breaker
12 Amp
12 Amp
5 Amp
GFCI
Yes
Yes
No
Technical Specifications
Содержание Pioneer Eclipse PE250AP
Страница 1: ...Commercial Air Purifier PE250AP Operator s Manual...
Страница 10: ...10 Wiring Diagram...
Страница 14: ...14 Lower Assembly 1 2 2 3 3 3 3 4 5 6 7 8 9 10 11 12 16 20 21 22 23 24 25 27 26 17 18 19 15...
Страница 17: ...17...
Страница 18: ...18...
Страница 19: ...19...