-32-
Troubleshooting
If any fault or abnormality occurs, immediately shut down the power supply and check and inspect the
machine for the followings before contacting your local Amano Dealer.
Problem
Cause
Handling
Will not start.
①
No power supply
②
Power failure
③
Seized rotational disc
→
Check the wiring of the power supply
and the protective device on the
linked equipment (machine tool).
→
Wait for power to resume.
→
Turn the power off and contact the
dealer where the product was
purchased or Amano
’
s branch or sales
office.
Abnormal sounds
①
The machine is running on
single-phase power since the
power cord is disconnected.
→
Replace the power cord.
Poor air intake
①
Reverse rotation of motor
②
Defective joints of ducts/hoses
③
Contamination inside cyclone
④
Clogged collection disc
→
Re-connect the two conductors of
3-phase power cord conductors to
change their phases each other for
correcting motor rotation direction.
→
Check ducts/hoses for any defects or
faulty joints and rework or replace at
need.
→
Remove the contamination from
inside the cyclone.
→
Clean the disc.
(Refer to the page 24)
Sudden stop during running
①
Faulty drain oil
②
Clogged collection disc
→
Drain the oil properly.
→
Clean the collection disc.
Mist blowing out of outlet
hole
①
Oil drain failure
→
Drain properly.
(Refer to the page 21)
Vibration,
abnormal noise/smell
①
Faulty rotation of motor, collection
disc, or fan
→
Turn the power off and contact the
dealer where the product was
purchased or Amano
’
s branch or sales
office.