Amanda Portal on Norstar
Integration Notes
April 9, 2003
1
Introduction
Intel/Dialogic make a pair of boards, D/42JCT-U (4 port) and D/82JCT-U
(8 port), which provide digital integration with a variety of telephone switches
using station set emulation. This line of boards is known as the PBX Integration
series, and the following switches are supported:
Manufacturer
PBX Hardware
Telephone Emulations
Lucent
Definity System 75/85
7434 (4-wire)
Definity System G3 Ver. 4
8434 (2-wire)
Siemens
ROLM 9005 and 9006
ROLMphone 400 (RP400)
Hicom 150E and 300E
Optiset E
Mitel
SX-50
Superset 420 (DNIC)
SX-200ML
Superset 430 (DNIC)
SX-2000
Nortel
Norstar
M7324
Meridian 1
M2616
This document describes the particular integration and switch setting issues
involved in connecting Amanda Portal with a Norstar switch.
2
Dialogic Driver Settings
Basically, you just follow the instructions in
Installing Amanda Portal
to install
the boards and driver. On the Miscellaneous tab of the Dialogic Configuration
Manager (DCM), for the firmware load, you will want to choose D82UCSP.fwl
1