Amana W10233410A Скачать руководство пользователя страница 4

4

INSTALLATION INSTRUCTIONS

Tools and Parts

G

ather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed 
here. 

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that 
opens to 1" (25.4 mm) or 
hex-head socket wrench 
(for adjusting dryer feet)

Wire stripper (for direct 

 

wire installations)

Level

Vent clamps

Caulking gun and 
compound (for installing 
new exhaust vent)

Tin snips (new vent 
installations)

¼" nut driver or socket 
wrench (recommended)

Tape measure

Parts supplie

d

Remove parts package from dryer drum. Check that all parts are 
included.

4 Leveling legs

NOTE:

 Do not use leveling legs if installing the dryer on a 

pedestal.

Parts nee

d

e

d

Check local codes. Check existing electrical supply and venting. 
See “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.

For close-clearance installations between 28.65" (728 mm) 
and 34.15" (867 mm), see “Plan Vent System” section for 
venting requirements.

    

3

4.15"

(867.4 mm)

Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please refer to the “Assistance 
or Service” section.

If using a power supply cor

d

:

Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 

 

120/240 volt minimum. The cord should be type SRD or 
SRDT and be at least 4 ft (1.22 m) long. The wires that 
connect to the dryer must end in ring terminals or spade 
terminals with upturned ends.

A UL listed strain relief.

Optional Pedestal

Are you placing the dryer on a pedestal? You have the option of 
purchasing pedestals of different heights separately for this dryer. 
You may select a 10" (254 mm) pedestal or a 15.5" (394 mm) 
pedestal with a storage drawer. The pedestal will add to the total 
height of the dryer for a total height of approximately 
46" (1168 mm) or 51.5" (1308 mm), respectively.     

For a garage installation, you will need to place the 10" (254 mm) 
pedestal at least 9" (229 mm) above the floor. You will need to 
place the 15.5" (394 mm) pedestal at least 3" (76 mm) above the 
floor.    

Optional pedestal (15.5" [394 mm] model shown)

To order, call the dealer from whom you purchased your dryer or 
refer to the “Assistance or Service” section.

Pe

d

estal Height

Color

Part Num

b

er

10

"

 (254 mm)

White

WHP1000SQ

15.5

"

 (394 mm)

White

XHP1550VW

Stack Kit

Are you planning to stack your washer and dryer? To do so, you 
will need to purchase a Stack Kit.

To order, call the dealer from whom you purchased your washer 
or refer to the “Assistance or Service” section. Ask for Part 
Number 8572546.

Location Requirements 

You will nee

d

A location that allows for proper exhaust installation. See 
“Venting Requirements.”

A separate 30-amp circuit.

Содержание W10233410A

Страница 1: ...RONIC ELECTRIC DRYERS Use CareGuide For questions about features operation performance parts accessories or service call 1 800 843 0304 or visit our website at www amana com Table of Contents 2 W10233...

Страница 2: ...ing Accumulated Lint 24 Vacation and Moving Care 25 Changing the Drum Light 25 TROUBLESHOOTING 25 Dryer Operation 25 Dryer Results 26 ASSISTANCE OR SERVICE 27 WARRANTY 28 You You can be killed or seri...

Страница 3: ...3...

Страница 4: ...use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that conn...

Страница 5: ...Most installations require a minimum 5 127 mm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The foll...

Страница 6: ...ire Protection Association One Batterymarch Park Quincy MA 02269 To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical sup...

Страница 7: ...auge copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover If your outle...

Страница 8: ...st be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electr...

Страница 9: ...ng instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA Type 14...

Страница 10: ...ion Now go to Venting Requirements 4 wire connection Direct wire IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections Direct wir...

Страница 11: ...Use where local codes permit connecting cabinet ground conductor to neutral wire A B D C E F G A 3 wire receptacle NEMA type 10 30R B 3 wire plug C Neutral prong D Spade terminals with upturned ends E...

Страница 12: ...under the outer terminal block screws hooks facing right Squeeze hooked ends together Tighten screws 4 Tighten strain relief screw 5 Insert tab of terminal block cover into slot of dryer rear panel Se...

Страница 13: ...arts and Accessories For more information see the Assistance or Service section Rigid metal vent For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid...

Страница 14: ...E Clamps F Rigid metal or flexible metal vent G Vent length necessary to connect elbows H Exhaust outlet Optional exhaust installations This dryer can be converted to exhaust out the right side left...

Страница 15: ...length and elbows needed for best drying performance Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer tha...

Страница 16: ...e exhaust hood Check that the vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer into its final location Do not crush or kink vent 3 On gas models Check that there are no kinks in the...

Страница 17: ...oor 4 Check for fingerprints on the glass Clean glass if necessary 5 Place the inner door assembly inside the outer door assembly To fit correctly the inner door assembly edge fits completely inside t...

Страница 18: ...interior thoroughly with a damp cloth to remove any dust 10 Select a Timed Dry heated cycle and start the dryer Do not select the Air Dry Temperature setting If the dryer will not start check the foll...

Страница 19: ...ate The estimated auto cycle or actual timed cycle time in minutes will show in the display NOTE A default time is displayed when an auto cycle is selected During the first few minutes of the drying p...

Страница 20: ...cle is running the display shows the estimated cycle time which is determined by your dryer automatically sensing the dryness level of your load If a Timed Cycle is running the display shows the exact...

Страница 21: ...rics such as sturdy work clothes Casual Use this cycle to get low heat for drying no iron fabrics such as sport shirts casual business clothes and permanent press blends Delicate Use this cycle to get...

Страница 22: ...ENT the dryer stops after cool down Cycle Signal The Cycle Signal produces an audible sound when the drying cycle is finished Promptly removing clothes at the end of the cycle reduces wrinkling Press...

Страница 23: ...by using the Air Dry temperature setting 7 You may change the cycle time by pressing MORE TIME or LESS TIME Reset time as needed to complete drying Refer to the following table 8 Press and hold START...

Страница 24: ...he dryer to stop before your load is completely dry The screen is probably clogged if lint falls off while the screen is in the dryer Clean the lint screen with a nylon brush every 6 months or more fr...

Страница 25: ...ING First try the solutions suggested here and possibly avoid the cost of a service call Dryer Operation Dryer will not run Has a fuse blown or has a circuit breaker tripped There may be 2 fuses or ci...

Страница 26: ...ly one fabric softener sheet and use it only once Is the exhaust vent the correct length Check that the exhaust vent is not too long or has too many turns Long venting will increase drying times See P...

Страница 27: ...d help follow the instructions below When calling please know the purchase date and the complete model and serial number of your appliance This information will help us to better respond to your reque...

Страница 28: ...installation instructions 10 Replacement parts or repair labor on major appliances with original model serial numbers that have been removed altered or cannot be easily determined DISCLAIMER OF IMPLIE...

Отзывы: