Component Testing Information

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to dryer before servicing,  
unless testing requires it. 
 

June 2004 

16023153  Rev. 0 

© 2004 Maytag Services

 

3

 

Illustration Component 

Test 

Procedure 

Results 

 

 

Heating element 

Measure resistance of element from 
terminal to terminal. 
 
 

 
10.01 

  9.43 

 

 

 

Motor 

See “Internal Motor Diagram and 
Schematic” section. 

See following section “Internal Motor 
Diagram and Schematic” for correct 
wiring contacts.

 

 
 

Belt 

Verify belt is not damaged or slipping. 

Wipe excess oil from cylinder, motor 
pulley, and belt, to prevent slippage. 
Replace belt if damaged. 

 
 

Cylinder seal 

Verify air leakage is not present 
around cylinder seal. 

Replace seal, if indication of leakage. 

 
 

Cylinder glide 

Verify glides are not damaged. 

Replace all glides when replacing any 
glides. 

 

 

Sensor 

Remove wires from sensor terminals 
 
 
Terminal to terminal ..........................  

Any indication other than 0 

, replace 

sensor. 
 

 

Содержание SDE515DAYW

Страница 1: ...avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it Models SDE515DAY Models SDE515DAY Power Source Temperature settings 4 Vol...

Страница 2: ...S P D T 3 terminals Measure resistance of the following terminals Terminals 1 3 Heat thermostat with a small flame until a distinct click is heard Terminals 1 2 Open at 225 7 F Close at 185 9 F Contin...

Страница 3: ...tor Diagram and Schematic section See following section Internal Motor Diagram and Schematic for correct wiring contacts Belt Verify belt is not damaged or slipping Wipe excess oil from cylinder motor...

Страница 4: ...ry or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 4 R R S 2 6 4 3 5 1 MAIN START ORANGE CUSTOMER CIRCUIT OVERLOAD PROTECTO...

Страница 5: ...ellow wire Manually depress actuator Continuity broken between switch terminal 6 and Yellow wire Continuity broken between switch terminal 1 and switch terminal 2 Manually depress actuator Continuity...

Страница 6: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 6 Ser...

Страница 7: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it June 2004 16023153 Rev 0 2004 Maytag Services 7 Ser...

Страница 8: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 8 Ser...

Отзывы: