Component Testing Information

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to dryer before servicing,  
unless testing requires it. 
 

16023153  Rev. 0 

June 2004 

 

 

© 2004 Maytag Services

 

2

 

Illustration Component 

Test 

Procedure 

Results 

 

Thermal fuse 

Measure resistance of thermal fuse from 
terminal to terminal. 
 
Open at 360

°

 

±

 12

°

 F (182

°

 

±

 7

°

 C)....  

Auto reset 

31

°

 F (

35

°

 C) 

If thermal fuse is open, both 
thermal fuse and thermostat limit 

must be replaced

Continuity < 

 

Pink / White  

 

Thermostat cycling 
 
S.P.D.T. 

 3 terminals 

Measure resistance of the following terminals: 
 

Terminals 1 

  3...............................  

Heat thermostat with a small flame until a 
distinct click is heard. 

Terminals 1 

  2...............................  

Open at 153

°

 

±

 5

°

 F 

Close at 138

°

 

±

 5

°

 F 

Continuity < 

 

 
 
Continuity < 

 

Orange  

 

Thermostat limit 
 
S.P.D.T. 

 3 terminals 

Measure resistance of the following terminals: 
 

Terminals 1 

  3...............................  

Heat thermostat with a small flame until a 
distinct click is heard. 

Terminals 1 

  2...............................  

Open at 225

°

 

±

 7

°

 F 

Close at 185

°

 

±

 9

°

 F 

Continuity < 

 

 
 
Continuity < 

 

 

 

Thermostat heater 

Disconnect wire terminals and measure 
resistance of terminals. 
 
Terminal to terminal ..........................  

 
 
 
2400   

±

 240 

 

 

 

Door switch 
 

  COM 

  N.C. 

  N.O. 

Measure resistance of the switch: 
Door closed 

Terminals 1 

  3...............................  

Door opened 

Terminals 1 

  2...............................  

 
 
Continuity < 

 

 
Continuity < 

 

 

 

Rocker switch 
(Extended Tumble) 

Measure resistance of switch positions: 
 ON    (Closed position) ....................  
 OFF   (Open position) ......................  

 
Continuity < 

 

Infinite 

 

> 1 M

 

 

 

Temperature switch  
  4 position 

Disconnect wires from component. Measure 
resistance of the switch in the following 
positions: 

 
 
 
 
Infinite  

> 1 M

 

Continuity  

< 1 

 

Continuity  

< 1 

 

Continuity  

< 1 

 

Continuity  

< 1 

 

 

 

 

Timer 

Verify input and output voltage is present. 

Refer to specific model 
Technical Sheet for timing 
sequence chart and functional 
description of the component. 

Содержание SDE515DAYW

Страница 1: ...avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it Models SDE515DAY Models SDE515DAY Power Source Temperature settings 4 Vol...

Страница 2: ...S P D T 3 terminals Measure resistance of the following terminals Terminals 1 3 Heat thermostat with a small flame until a distinct click is heard Terminals 1 2 Open at 225 7 F Close at 185 9 F Contin...

Страница 3: ...tor Diagram and Schematic section See following section Internal Motor Diagram and Schematic for correct wiring contacts Belt Verify belt is not damaged or slipping Wipe excess oil from cylinder motor...

Страница 4: ...ry or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 4 R R S 2 6 4 3 5 1 MAIN START ORANGE CUSTOMER CIRCUIT OVERLOAD PROTECTO...

Страница 5: ...ellow wire Manually depress actuator Continuity broken between switch terminal 6 and Yellow wire Continuity broken between switch terminal 1 and switch terminal 2 Manually depress actuator Continuity...

Страница 6: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 6 Ser...

Страница 7: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it June 2004 16023153 Rev 0 2004 Maytag Services 7 Ser...

Страница 8: ...d Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires it 16023153 Rev 0 June 2004 2004 Maytag Services 8 Ser...