Vent Control Assembly Removal
To remove vent control assembly:
1. Remove outer case (see paragraph
Outer Case
Removal).
2. Remove two ¼-inch screws securing top cover to
chassis, then pull top cover up and away.
3. Remove ¼-inch screw securing vent door to partition
panel.
4. Remove Phillips head screw securing vent door slide
to control panel.
5. Lift vent control assembly out and away from chassis.
Vent Control Removal
Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and
discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require
power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or
operational.
Electronic Control Removal
To remove electronic control:
1. Remove outer case (see paragraph
Outer Case
Removal).
2. Discharge capacitor through 10,000 ohm resistor.
3 Disconnect connector plug between control and
wiring harness.
4. Remove four Phillips head screws securing electronic
control to control panel.
5. Remove thermostat sensor from thermostat sensor
mounting clip on front of evaporator.
6. Carefully work electronic control and attached
thermostat sensor out and away from control panel.
Electronic Control Removal
Control
panel
Electronic
control
Vent
door
slide
Vent door
Top cover