background image

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation
to know the product better than the customer.  This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize
yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during
installation or repair it is possible to place yourself
in a position which is more hazardous than when
the unit is in operation.

Remember, it is your responsibility to install the
product safely and to know it well enough to be
able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of
thinking before acting. Most dealers have a list of
specific good safety practices...follow them.
The precautions listed in this Installation Manual
are intended as supplemental to existing practices.
However, if there is a direct conflict between existing
practices and the content of this manual, the
precautions listed here take precedence.

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

Goodman Company, L.P.

1810 Wilson Parkway  •  Fayetteville, Tennessee  37334

www.amana-hac.com

(RHA**B*D/VHA**B*A)

Remote Heat Pump

January 2003

Table of Contents

Safety Instructions ............................................................. 2

General ................................................................................3

SHIPPING AND HANDLING ............................................................. 3
LOCATION AND CLEARANCES ...................................................... 3
ROOFTOP INSTALLATIONS ............................................................ 3
APPLICATION NOTE ........................................................................ 3

Refrigerant Piping .....................................................3

REFRIGERANT VAPOR AND LIQUID LINE SIZING ....................... 3
REFRIGERANT VAPOR AND LIQUID LINE ROUTING ................... 4
SWEAT CONNECTIONS AT THE UNIT ........................................... 4

Safe Refrigerant Handling ................................................. 4

LEAK TESTING ................................................................................. 5
ID COIL AND LINE SETS EVACUATION .......................................... 5

Step 1.  Confirm Proper Pump And Gauge Operation .............. 5
Step 2.  Evacuate Lines And Indoor Coil. ................................. 6

Electrical Connections ....................................................... 7

WIRING ............................................................................................. 7

System Startup ................................................................... 8

PRELIMINARY CHARGE ADJUSTMENT ......................................... 8
FINAL CHARGE ADJUSTMENT ....................................................... 8

Matching System ....................................................................... 8
AMANA-Approved Mix-Matched System Combinations ........... 8

ID COIL WITH EXPANSION VALVE ................................................. 8
ID COIL WITH ORIFICE .................................................................. 10

Troubleshooting ............................................................... 10

Defrost System ....................................................... 10

Installation Instructions

Affix this manual, Specification Sheet and Users

Information Manual adjacent to the unit.

R

C

R

C om fort. Q uality. Tru st.

Heating

®

&

Air Conditioning

Part No. 10845809 Rev. 1
Printed in USA

Содержание RHA Series

Страница 1: ...utions listed here take precedence RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION Goodman Company L P 1810 Wilson Parkway Fayetteville Tennessee 37334 www amana hac com RHA B D VHA B A Remote Heat Pump...

Страница 2: ...throughout this manual to indicate immediate or potential safety hazards It is the owner s and installer s responsibility to read and comply with all safety information and instructions accompanying...

Страница 3: ...ne lengths of fifty feet or less and indoor coil elevations of no more than forty feet above or below the outdoor unit NOTE Unit performance is affected by vapor line tubing size A larger than require...

Страница 4: ...them first dig the trench so that it gradually slopes toward the compressor at least 1 inch per 10 feet Then insulate the liquid and suction lines separately Enclose all under ground portions of the...

Страница 5: ...s a through c again Otherwise the pump and gauge are operating properly and you can continue on to the next step evacuating the system Before proceeding be sure to close the valve D to the vacuum gaug...

Страница 6: ...ns or less d Close the valve to the vacuum pump C Wait five minutes then check the pressure on the vacuum gauge 1 If the pressure is not more than 1500 microns the system is leak free and properly eva...

Страница 7: ...y route the power supply and ground wires through the high voltage entrance in the unit 2 Connect the ground wire to the ground lug and power supply wires to the contactor 3 Route the low voltage wiri...

Страница 8: ...oz of R 22 per deviating foot CAUTION Using refrigerant that does not meet ARI Standard700maycausecompressordam age and void the warranty IMPORTANT If adding refrigerant to a system add only refriger...

Страница 9: ...100 110 120 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 SUPERHEAT O D UNIT OUTDOOR TEMPERATURE DESIRED SUPERHEAT vs OUTDOOR TEMPERATURE 9 0 F I n d o o r 70 F Indoor 7 5 F I n d o o r 8 0 F I n d o...

Страница 10: ...e 350 to 450 CFM per ton of cooling based on the size of the outdoor unit If further information is needed see the Remote Heat Pump Service Manual or contact your Amana distributor Defrost System Your...

Страница 11: ...ccessories wiring may have to be modified Follow the instructions in the accessory kit s installation instructions WARNING To avoid personal injury shock or death disconnect the electrical power befor...

Страница 12: ...or Is it within the limits shown on the nameplate of the motor 16 Are all access panels installed and secured 17 Do controls function properly Are manual reset switches in the reset position high pres...