5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective PCB
assembly
Replace PCB
assembly
Disconnect the
wire leads from
relay 3,5 or relay
4,6 and check
continuity of relay 3,5
or relay 4,6
(Operate the unit)
Abnormal
Normal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer
Normal
Normal
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and blower motor run.
(Display operates properly)
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 3,5 or relay
4,6 and check
continuity of relay 3,5
or relay 4,6
(Operate the unit)
Defective PCB
assembly.
Replace PCB
assembly.
NOTE : • Make sure the wire leads are in the correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание RFS12SW2C
Страница 12: ...SCHEMATIC DIAGRAM 4 6 ...
Страница 30: ... 6 2 DOOR PARTS 1384 W136 1006 1007 W108 W105 1386 1009 W207 W206 1385 1004 1005 1013 1000 1002 EV ...
Страница 31: ...CONTROL PANEL PARTS 6 3 2004 2006 2381 2000 W130 W102 EV ...
Страница 33: ...LARCH BOARD PARTS 6 5 4003 4000 4009 W102 W160 4002 4004 4008 4001 EV ...
Страница 35: ...BASE PLATE PARTS 6 7 5008 9001 6001 6000 W101 W101 W121 W108 6013 W121 3026 3901 3902 W162 5061 5022 EV ...
Страница 36: ...P No MFL05869703 ...