F. MAGNETRON REMOVAL
1) Disconnect the lead wire from the magnetron.
2) Remove the duct ASS'Y.
3) Carefully remove the mounting screws holding the
magnetron and the waveguide.
4) Remove the magnetron ASS’Y until the tube is
clear from the waveguide.
NOTE:
1. When removing the magnetron, make sure its
dome does not hit any adjacent parts, or it may be
damaged.
2. When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and
be sure that the gasket is in good condition.
3. After replacing the magnetron, check for microwave
leakage with a survey meter around the magnetron.
Microwave energy must be below the limit of 5
mW/cm
2
. (With a 275 ml. water load).
Make sure that gasket is rigidly attached to the
magnetron.
To prevent microwave leakage, tighten
the mounting screws properly, making sure there is
no gap between the waveguide and the magnetron.
G. REMOVING THE BOTTOM STIRRER
FAN MOTOR
1) Lay the unit down on its back.
2) Remove the screw securing the base cover.
3) Disconnect the leadwire from the stirrer fan motor
terminals.
4) Remove the screw securing the stirrer fan motor to
the oven cavity ASS’Y
5) After repairing the motor, replace the removed
base cover.
6) The taptite screw shall be used when a turntable
motor cover is secured with a screw.
NOTE:
1. Remove the wire lead from the stirrer fan motor
VERY CAREFULLY.
2. Be sure to grasp the connector, not the wires, when
removing.
5-5
Magnetron
Base cover
Taptite Screw
Wire Leads
Stirrer Fan Motor
Magnetron
Содержание RFS12SW2C
Страница 12: ...SCHEMATIC DIAGRAM 4 6 ...
Страница 30: ... 6 2 DOOR PARTS 1384 W136 1006 1007 W108 W105 1386 1009 W207 W206 1385 1004 1005 1013 1000 1002 EV ...
Страница 31: ...CONTROL PANEL PARTS 6 3 2004 2006 2381 2000 W130 W102 EV ...
Страница 33: ...LARCH BOARD PARTS 6 5 4003 4000 4009 W102 W160 4002 4004 4008 4001 EV ...
Страница 35: ...BASE PLATE PARTS 6 7 5008 9001 6001 6000 W101 W101 W121 W108 6013 W121 3026 3901 3902 W162 5061 5022 EV ...
Страница 36: ...P No MFL05869703 ...