Amana PTAC DS02G-H Скачать руководство пользователя страница 5

5

Final Assembly

1. Slide top of the thermostat down at a slight angle and

press onto the mounting base plate to snap into place.

2. Provided optional security screw may be used in the

lower center of the thermostat.

Optional Security Screw 

Note: It is recommended that the installer do a 

functional check on unit after the thermostat is 

installed and power is restored.

Basic Operation

The MODE button allows for selection of mode of operation 

between Off or Auto-changeover. 

The FAN button adjusts fan speeds between low fan, high 

fan and automatic fan (where the thermostat determines 

the most appropriate speed). The FAN button also allows 

for the selection of Fan Only mode from the Off mode if air

circulation is desires without temperature conditioning the 

room.

The (+) and (–) buttons allow the temperature setting to be 

adjusted.

Binding Operation (for Zigbee network)

To Join the thermostat to a Zigbee network, the Zigbee 

network must be in discover mode; entering customer’s 

network into discover mode is dependent upon the 

Zigbee gateway used. When the Zigbee network is in 

discover mode, press and hold the MODE and (+) buttons 

simultaneously on the thermostat until the displays shows 

“00”. The Dot symbol on LCD display starts blinking which 

indicates it’s in discoverable mode. The discoverable 

mode will last for 30 seconds. Once Zigbee Network 

joining process is successful, the dot in the lower left of the 

display stops flashing and goes solid and LCD backlight

will start blinking till Identify time expires. The network short 

address for identifying this device on the network may be 

determined by entering configuration settings per above

and viewing the two values in the “nA” configuration code

The thermostat may be removed from Zigbee network by 

holding the MODE and (-) buttons simultaneously until the 

dot in the lower left of the display blinks. The thermostat 

goes into discoverable mode again and stops blinking after 

30 seconds. The dot should not be displayed if thermostat 

left the Zigbee network successful.

Note: Once a thermostat has been bound to Zigbee 

network, it must be removed from that network 

per the instructions above before binding it to a 

new network.

CAUTION

This equipment is authorized for use under the 

United States Federal Communication Rules 

and Regulations, Code of Federal Regulations 

Chapter 47 part 15 and must be installed in 

accordance with the instructions provided in 

this document. Failure to install or operate 

this equipment as instructed in this document 

could void the user’s authority to operate 

the equipment. This equipment countains no 

user serviceable parts. Any modification or 

repairs to the internal components or to the 

antenna configuration of the equipment without 

the antenna configuration of the equipment 

without the express written consent of Everex 

Communications, Inc., could void the user’s 

authority to operate the equipment. 

NOTE: To comply with FCC RF exposure 

requirements in Section 1.1307, a minimum 

separation distance of 20-cm (8 inches) is required 

between the equipment and all persons.

NOTE: This equipment has been tested and found 

to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable 

protection against harmful interference in a 

residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, 

if not installed and used in accordance with the 

instructions, may cause harmful interference 

to radio communications. However, there is 

no guarantee that interference will occur 

in a particular installation. If this equipment 

does cause harmful interference to radio and 

television reception, which can be determined 

by turning the equipment off and on, the user is 

encouraged to try to correct the interference by 

one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and

receiver.

• Consult the dealer or an experienced radio/TV

technician for help.

Содержание PTAC DS02G-H

Страница 1: ...damage personal injury or death WARNING is a registered trademark of Maytag Corporation or its related companies and is used under license All rights reserved As a professional installer you have an o...

Страница 2: ...es instructions 7 If mounting thermostat with wiring compartment recessed into drywall cut drywall opening 2 wide by 2 7 8 tall in desired location The flush moun base extension may be used as a templ...

Страница 3: ...pears Use the or buttons to select o for an O terminal reversing valve energizes on cooling and b for a B terminal reversing valve energizes on heating 6 Press and release the FAN button until HE appe...

Страница 4: ...90 82 db Auto Changeover Deadband C 1 0 2 5 2 2 C 1 8 4 5 4 0 F 1 0 2 5 2 2 CF Display F or C Temperatures Fahrenheit Scale F Celsius Scale C LC Compressor Lockout Minimum 3 minute Compressor Lockout...

Страница 5: ...d stops blinking after 30 seconds The dot should not be displayed if thermostat left the Zigbee network successful Note Once a thermostat has been bound to Zigbee network it must be removed from that...

Страница 6: ...6 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 7: ...7 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 8: ...is a registered trademark of Maytag Corporation or its related companies and is used under license All rights reserved PTAC DIRECT SALES INC 185 S Kimball Ave Suite 130 Southlake TX 76092 877 454 7822...

Отзывы: