OPERATION AND SERVICE PROCEDURES
Electronic Range Control (ERC) (Models w/Two Piece Control)
RC231002 Rev. 3
36
TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER
BEFORE SERVICING, UNLESS TESTING REQUIRES IT.
TERMINALS
/PINS
CIRCUIT TESTED
APPROXIMATE
OHMS READINGS
J1-1 TO J1-2
J1-1 TO J1-3
J1-5 TO J1-6
J1-7 TO J1-8
E1 TO E2
E4 TO E5
E6 TO E7
BAKE RELAY COIL
BROIL RELAY COIL
TRANSFORMER SECONDARY WINDING
TRANSFORMER SECONDARY WINDING
TRANSFORMER PRIMARY WINDING
BROIL RELAY CONTACT
BAKE RELAY CONTACT
560 OHMS
560 OHMS
5-7 OHMS
2-4 OHMS
120-150 OHMS
INFINITE OHMS (OPEN)
INFINITE OHMS (OPEN)
Figure 37
Relay Board Schematic
NOTE:
Check each transformer terminal (J1-5, J1-6, J1-
7, J1-8, E1 and E2) in turn to ground terminal E3. All
readings must be infinite (OPEN).
Figure 36
Relay/Power Supply Circuit Board
Terminal/Pin Locations