filed immediately with the shipping company. Check the unit
model number, specifications, electrical characteristics and
accessories to determine if they are correct. In the event an
incorrect unit is shipped, it must be returned to the supplier
and must NOT be installed. The manufacturer assumes no
responsibility for installation of incorrectly shipped units.

R

EPLACEMENT

 P

ARTS

O

RDERING

 P

ARTS

When reporting shortages or damages, or ordering repair
parts, give the complete unit model and serial numbers as
stamped on the unit’s nameplate.

Replacement parts for this appliance are available through
your contractor or local distributor. For the location of your
nearest distributor, consult the white business pages, the
yellow page section of the local telephone book or contact:

SERVICE PARTS DEPARTMENT

GOODMAN MANUFACTURING COMPANY, L.P.

5151 SAN FELIPE, SUITE 500

HOUSTON, TEXAS 77056

(713) 861 – 2500

I

MPORTANT

 S

AFETY

 I

NSTRUCTIONS

R

ECOGNIZE

 S

AFETY

 S

YMBOLS

, W

ORDS

AND

 L

ABELS

The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner’s responsibility to read and comply with all safety in-
formation and instructions accompanying these symbols.  Fail-
ure to heed safety information increases the risk of property
damage, product damage, personal injury or death.

HIGH

 

VOLTAGE!

D

ISCONNECT

 

ALL

 

POWER

 

BEFORE

 

SERVICING

.

 

M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

.

 

F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

,

 

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

ONLY

 

INDIVIDUALS

 

MEETING

 

THE

 

REQUIREMENTS

 

OF

 

AN

 

“E

NTRY

 

L

EVEL

 

T

ECHNICIAN

”,

 

Y

 

USE

 

THIS

 

INFORMATION

.

 

A

TTEMPTING

 

TO

 

INSTALL

 

OR

 

REPAIR

 

THIS

 

UNIT

 

WITHOUT

 

SUCH

 

BACKGROUND

 

MAY

 

RESULT

 

IN

 

PRODUCT

 

DAMAGE

,

 

PERSONAL

 

INJURY

,

 

OR

 

DEATH

.

AT

 

A

 

MINIMUM

,

 

AS

 

SPECIFIED

 

BY

 

THE

 

A

IR

 

C

ONDITIONING

,

 

H

EATING

 

AND

 

R

EFRIGERATION

 

I

NSTITUTE

 

(AHRI)

 

MA

WARNING

 

 
 
 
 
 
 
 
 

 

 

 

CARBON MONOXIDE POISONING HAZARD  

-

 

 

Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas

Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions.  If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.

This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area.  Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.

CO can cause serious illness including permanent brain damage or death.

B10259-216

G

ENERAL

 I

NFORMATION

The MBVC Blower Cabinets are used in combination with a
cased evaporator coil.  This combination of blower and coil
functions as the indoor part of a split air-conditioning system,
and may be matched with a remote condensing or heat pump
unit.  The blower cabinet can also function as an electric fur-
nace when used with an electric heater.

NOTE:

The electric heating elements for  electric furnace

installation are not shipped with the cabinet and are field-
installed.

Systems should be properly sized by heat gain and loss cal-
culations made according to methods of the Air Conditioning
Contractors Association (ACCA) or equivalent.  It is the
contractor’s responsibility to ensure the system has adequate
capacity to heat or cool the conditioned space.

F

EATURES

This modular blower is a part of the ComfortNet™ family of
products.  It may be installed as part of a “legacy” system
using a standard 24 VAC thermostat.  However, with the
CTK01AA ComfortNet™ thermostat kit, this modular blower
may be installed as part of a digitally communicating system.
The ComfortNet™ system provides automatic airflow con-
figuration, enhanced setup features, and enhanced diagnos-
tics.  It also reduces the number of thermostat wires to a
maximum of four.

C

LEARANCES

 A

ND

 A

CCESSIBILITY

The unit can be positioned for upflow, counterflow, horizontal
right or horizontal left operation.  Zero clearance is allowed

Содержание MBVC

Страница 1: ...1 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com or www amana hac com P N IO 344C Date November 2010 3 Service integrated control module or connecting wiring following the discharge process in step 2 Use caution not to recharge your body with static electricity i e do not move or shuffle your feet do not touch ungrounded objects etc If you come in contact with an ungrounded object repeat...

Страница 2: ...mobile space heater gas water heater etc should not be operated in enclosed areas such as unventilated garages utility rooms or parking areas because of the danger of carbon monoxide CO poisoning resulting from the exhaust emissions If a furnace or air handler is installed in an enclosed area such as a garage utility room or parking area and a carbon monoxide producing device is operated therein t...

Страница 3: ...inet assembly and all attached ductwork 2 Connect refrigerant and condensate drain connections per the evaporator coil installation instructions Ensure refrigerant and drain lines do not interfere with service access to the unit 3 Attach supply ductwork Seal connections between unit and ductwork as required to reduce eliminate air leakage 4 Make electrical connections as specified in Electrical Co...

Страница 4: ... W ARNI NG SO FTW ARE VER TOP FRONT VIEW Figure 6 MBVC Motor Orientation ELECTRICAL CONNECTIONS Consult the local power company and local codes before in stalling this unit All wiring must be in accordance with the National Electrical Code as well as all local codes Knock outs have been provided on side and top of the cabinet for the installation of the electrical conduit If the knockouts on the c...

Страница 5: ...le Stage Heat Thermostat Dehumidistat Optional Remote Condensing Unit Single Stage AC NEU HOT 1 2 R C G W1 Y1 Y2 O DEHUM R C G W1 Y1 R C Y Place Jumper Between Y1 and O for Proper Dehumidification Operation and Proper Ramping Profile Operation W2 Figure 7 Typical Single Stage Cooling with Single Stage Heating Air Handler Integrated Control Module Typical Two Stage Cool Two Stage Heat Thermostat De...

Страница 6: ...ication Sheet applicable to your model Look up the cooling air flow determined in step 2 and find the required cooling speed and adjustment setting Example A MBVC1200 modular blower installed with a 2 5 ton air conditioning system The air flow needed is 1000 CFM Looking at the cooling speed chart for MBVC1200 find the air flow closest to 1000 CFM A cooling airflow of 1000 CFM can be attained by se...

Страница 7: ... ON ON ON ON ON ON C OFF ON OFF ON OFF ON 1 Select model and desired high stage cooling airflow Determine the corresponding tap A B C or D Set dip switches 1 and 2 to the appropriate ON OFF positions 2 Select model and installed electric heater size Set switches 9 10 and 11 to the appropriate ON OFF positions 3 Select the airflow adjustment factor tap A and D are 0 Tap B is 10 Tap C 10 Set dip swi...

Страница 8: ...a blower Return any old or new controls to their containers before touching any ungrounded object DIAGNOSTIC CHART HIGH VOLTAGE TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK DISCONNECT ELECTRICAL POWER BEFORE PERFORMING ANY SERVICE OR MAINTENANCE WARNING Refer to the Troubleshooting Chart at the end of this manual for assistance in determining the source of unit operational problems Th...

Страница 9: ...gured for a low medium or high continuous fan speed The low medium and high fan speeds correspond to 25 50 and 75 respectively of the air handlers maximum airflow capability During continuous fan operation the thermostat sends a fan request along with the continuous fan demand to the air handler The air handler in turn sends the demand to the ECM motor The ECM motor delivers the requested continuo...

Страница 10: ...oor or outdoor equipment If a fault is present the Fault Screen will show the equipment and an error code with a description of the fault Touch _ or keys to view the fault status of any remaining equipment The text NO FAULTS will be scrolled if no errors are present Menu Run Schedule Call for Service Advanced Menu Run Schedule Call for Service Advanced Touch the or _ to step through the list of in...

Страница 11: ...y only Fault 5 FAULT 5 Next most recent fault For display only Fault 6 FAULT 6 Least recent fault For display only Clear Fault History CLEAR NO or YES Selecting YES clears the fault history NOTE Consecutively repeated faults are shown a maximum of 3 times DIAGNOSTICS Submenu Item Indication for Display Only not User Modifiable Model Number MOD NUM Displays the modular blower model number Serial Nu...

Страница 12: ... Accessing and Navigating the Advanced Features Menus NOTE It is highly recommended that the fault history be cleared when performing maintenance or servicing the modular blower NETWORK TROUBLESHOOTING NOTE Indoor Unit BIAS and TERMINATION Dipswitches are factory set and should not be changed 1 2 ON OFF 3 BIAS BIAS TERM Indoor Unit BIAS and TERMINATION Dipswitches The ComfortNet system is a fully ...

Страница 13: ...a wire s x Modular blower is installed as a legacy traditional system x Check communications wiring data 1 data 2 wires x Check wire connections at terminal block x Verify modular blower installation type legacy traditional or communicating x Check data 1 data 2 voltages x Turn power OFF prior to repair x Verify wires at terminal blocks are securely twisted together prior to inserting into termina...

Страница 14: ...14 APPENDIX A ...

Страница 15: ...g power ON Memory card may be removed after data is loaded x Electric heat airflow is higher than expected on a call for W1 or Auxiliary Emergency heat x Integrated control module LED display provides the indicated error code 1 Flash x Heater kit selected via dipswitches does not heater kits specified in shared data set NO HTR MATCH Ec x Heater kit selected via dipswitches is doesn t match heater ...

Страница 16: ...rd for the specific model x Insert memory card BEFORE turning power ON Memory card may be removed after data is loaded x Error code will be cleared once data is loaded x Operation different than expected or no operation x Integrated control module LED display provides indicated error code x ComfortNet thermostat Call for Service icon illuminated x ComfortNet thermostat scrolls Check Air Handler me...

Страница 17: ...tor blower motor horse power MOTOR MISMATCH b2 x Incorrect circulator blower motor in modular blower x Incorrect shared data set in integrated control module x Verify circulator blower motor horse power is the same specified for the specific modular blower model Replace if necessary x Verify shared data set is correct for the specific model Re populate data using correct memory card if required x ...

Страница 18: ...emperatures x Check power to modular blower Verify line voltage to blower is within the range specified on the modular blower rating plate x See Installation Instructions for installation requirements x Turn power OFF prior to repair x Modular blower fails to operate x Integrated control module LED display provides indicated error code x ComfortNet thermostat Call for Service icon illuminated x Co...

Страница 19: ...MOSTAT CONNECTIONS GN GREEN TRANSFORMER HEAT SEQUENCER R2 GND FIELD GND INTERNAL TO TWO STAGE INTEGRATED CONTROL MODULE TX 3 DEHUM C W1 1 5 FIELD SPLICE W1 CFM LED R Y1 NOTES LOW VOLTAGE 24V 4 GND W1 24 V 3 A 4 RX 2 COLOR CODES Y2 TH STATUS LED 5 TO RECALL THE LAST 6 FAULTS MOST RECENT TO LEAST RECENT DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY N THERMOSTAT INPUTS 208 VAC Y1 VDC 1 TH I...

Страница 20: ...product failure They are simple to service and forgiving to operate We use quality materials and components Finally every unit is run tested before it leaves the factory That s why we know There s No Better Quality Visit our websites at www goodmanmfg com or www amana hac com for information on Products Warranties Customer Services Parts Contractor Programs and Training Financing Options 2009 2010...

Отзывы: