31
6. Replace burners and burner retention bracket, inspect
the burner assembly for proper seating of burners in
retention slots.
7. Reinstall the burner box front cover.
8. Turn on electric power and gas supply to the furnace.
9. Check furnace for proper operation.
Check the burner flames for:
1. Good adjustment
2. Stable, soft and blue
3. Not curling, floating, or lifting off.
Figure 41
Burner Flame
GENERAL INFORMATION
1. When ordering any of the listed functional parts, be
sure to provide the furnace model, manufacturing, and
serial numbers with the order.
2. Although only functional parts are shown in the parts
list, all sheet metal parts, doors, etc. may be ordered by
description.
3. Parts are available from your Amana distributor
Gas Valve
Blower/Box Gasket
Gas Orifice, Natural
Flame Rollout Switch
Gas Orifice, Propane
Auxiliary Limit
Burner
Heat Exchanger
Igniter
Door Switch
Flame Sensor
Transformer
Gas Manifold
Blower Wheel
Ignition Control
Blower Housing
Limit Switch
Blower Cutoff
Pressure Switch
Blower Motor
Pressure Switch Hose
Motor Mount Bracket
Induced Draft Blower
Capacitor
Collector Box