12
2.
Unplug or disconnect power.
3.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
NOTE:
Do not remove the spring beneath the cap.
4.
Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
5.
Turn the cap over so that LP is visible.
6.
Reinstall the cap.
To Convert Surface Burners
1.
Remove burner grate, burner caps, and burners.
A
B
A. Burner cap
B. Burner
A
A. Cap
GAS CONVERSIONS
LP Gas Conversion
To Convert Gas Pressure Regulator
1.
Ensure that the manual shutoff valve is in the closed position.
NOTE:
Gas conversions (from
N
atural gas to LP gas or from LP
gas to Natural gas) must be done by a qualified person.
A. Gas pressure regulator
A
A
B
C
A. Shutoff valve in “closed” position
B. Gas supply line
C. To range
A. Gas pressure regulator
Содержание FREESTANDING GAS RANGE