Important Information

Great pride and workmanship go into every Amana product to provide our Customers with the highest possible quality.
We realize, however, that during its lifetime the product may require service.  The information contained in this manual
is intended for use by a qualified Amana Service Technician who is familiar with the safety procedures required in the repair
and who is equipped with the proper tools and testing instruments.

WARNING

Repairs covered in this manual that are made by unqualified persons can result in hazards due to improper
assembly or adjustments subjecting inexperienced persons making such repairs to the risk of injury or electrical
shock which can be serious or even fatal.

CONSUMER INFORMATION LINE

AMANA TOLL FREE

1-877-254-4729 (U.S. only)

email us at: [email protected]

fax us at: (931) 438- 4362

(Not a technical assistance line for dealers.)

Outside the U.S., call 1-931-433-6101.

(Not a technical assistance line for dealers.)

Your telephone company will bill you for the call.

SHIPPING AND HANDLING

Units are securely packed in shipping containers approved by the International Safe Transit Association.  Check the carton
upon arrival for external damage.  If damage is found, file a request in writing for inspection by the carrier agent
immediately.  The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each
claim. The distributor or manufacturer will not accept claims from dealers for transportation damage.  If no damage is
found, carefully remove all shipping material and properly dispose of it.
Keep the unit as upright as  possible.  Laying the unit on its side or top could cause equipment damage.

TO THE INSTALLER

Before installing this unit please read this manual and the Specification Sheet to
familiarize  yourself on the specific items which must be adhered to such as
maximum external static pressure to unit, air temperature rise, minimum or
maximum CFM and motor speed connections.

TO THE OWNER

It is important to complete the owner registration card and mail it immediately. This
will assist us in contacting you if any service or warranty information should
change in the future. When completing the registration card, be sure to include the
Model, Manufacturing and Serial Numbers, plus the installation date.
The warranty certificate is also supplied with the unit. Read the warranty carefully
and note what is covered. Keep the warranty certificate in a safe place so you can
find it if necessary.
If additional operating instructions are required, call the dealer where the
purchase was made. Keep this literature in a safe place for future reference.

In order to locate an authorized Amana service agency, please consult your telephone book or the dealer from whom you
purchased this product.  If you require further assistance, please contact:

IMPORTANT NOTE TO CUSTOMER

CAUTION

If you perform service on your own Amana product, you must assume responsibility for any personal injury or
property damage that may result.  Amana will not be responsible for any injury or property damage arising from
improper service and/or service procedures.

Содержание DUCT MOUNT

Страница 1: ...nit is in operation Remember it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use Safety is a matter of common sense a m...

Страница 2: ...from dealers for transportation damage If no damage is found carefully remove all shipping material and properly dispose of it Keep the unit as upright as possible Laying the unit on its side or top c...

Страница 3: ...s on the air intake side A spring contact is located on the top of each cell and must be in position to make contact with the contact board assemblies on the bottom of the power tray assembly Fig 1 PR...

Страница 4: ...m off This is a part of the breaking in period of ownership and the issue is self correcting Also high altitude locations can be more susceptible to noticing the presence of ozone An ionizing collecti...

Страница 5: ...on the collector plates and cause nuisance arcing Arcing will reduce air cleaner efficiency and reduce the life of the high voltage power supply HUMIDIFIERS An evaporative humidifier can be mounted up...

Страница 6: ...plenum justabovethefurnace Figure 4 COUNTERFLOW FURNACE Mountedhorizontallyinreturnduct or plenum just above the furnace Figure 5 SPACE SAVER FURNACE HIGHBOY Side installation Cleaner is mountedvertic...

Страница 7: ...is set up for a left to right airflow when facing the access door For a right to left airflow follow these directions Figure 9 Figure 10 Figure 11 1 Remove the pre filter and cells from the cabinet A...

Страница 8: ...twork This hole is located on the right hand side of the cabinet that holds the power tray assembly when facing the unit The hole is 3 16 in diameter and is located on the front of the power tray asse...

Страница 9: ...Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Power can be supplied to the EAC6 by on...

Страница 10: ...al time for the electronic airflow sen sor to complete its stabilization period 3 Wait approximately one minute and turn the HVAC system blower to the ON position Both lights should illumi nate 4 Perf...

Страница 11: ...rty water 5 With a hose held approximately 10 above rinse the cells and pre filters Do not spray the ionizing wires directly as they may snap and or break Be sure to rinse the edges of the cell frame...

Страница 12: ...ng or sizzling noise Poor electrical contact Ensure that there is a good connection between the top of the ionizing collector cell and the bottom of the ocntact board assembly Contact HVAC contractor...

Страница 13: ...only These procedures are not to be attempted by any person who is not qualified to work with high voltage or who is not familiar with this type of air cleaner Amana cannot be held responsible for an...

Страница 14: ...21B multimeter or equivalent Fluke 80k 40 high voltage probe or equivalent The EAC6 is equipped with an input LED light green and a cell energized LED light red for indicating proper unit operation Wh...

Страница 15: ...witch and ON OFF switch at the safety interlock switch Connect a multimeter to the safety interlock switch and discon nected wire Depress the safety interlock switch The meter should indicate a contin...

Страница 16: ...cleaner off and remove both electronic cells from the cabinet Shut the door and re power the unit If the red cell energized light comes on an electrical short exists in one or both of the electronic...

Страница 17: ...6 Replace the access door and turn the unit ON This procedure will slightly reduce the output voltage minimize arcing and reduce ozone production If the condition does not improve repeat the above pr...

Страница 18: ...place any defective wires Using alcohol clean dirt buildup on contacts and let dry thoroughly Loose wires or bad power supply connections Repair or replace any loose wires or bad connections Defective...

Страница 19: ...or Kit 4 ON OFF Switch 5 Safety Interlock Switch 6 Cabinet Assembly 7 Pre Filter 2 required 8 Ionizing Collector Cell 9 Ionizing Wire Assembly 1 wire 10 Handle 11 Access Door 12 Contact Board Assembly...

Страница 20: ...centrations of corrosive agents causing deterioration of metal components OWNER SRESPONSIBILITIES Provide proof of purchase sales receipt Provide normal care and maintenance Make product reasonably ac...

Отзывы: