Amana distinctions DCP073A25AA Скачать руководство пользователя страница 4

4

WARNING

Al ways ensure effective earthing. Incorrect earthing ma

cause electric shock.

  

WARNING

Do not allow w ater t o run in electric p arts. It ma y cause 

failure of machine or electric shock.

WARNING

Al ways inst all  circuit breaker and a  dedicated power circuit . 

Incorrect inst alla tion may cause fire and electric shock.

WARNING

Do not use the socket if it is loose or damaged. It ma

y cause 

fire and electric shock.

WARNING

Do not open the unit during opera tion. It ma t cause electric 

shock.

WARNING

Keep firearms a way. It may cause fire.

WARNING

Do not use the power cord close t

o heating appliances. It ma y 

cause fire and electric shock.

WARNING

Do not use the power cord near flammable gas or combusti

-

bles, such as gasoline, benzene, thinner, et

c. It may cause an 

explosion or fire.

WARNING

Ventila te room before opera ting air conditioner if there is a

 

gas leakage from another appliance. It ma

y cause explosion, 

fire, and burns.

WARNING

Do not disassemble or modify  unit. It may cause f ailure and 

electric shock.

CAUTION

When the air fil ter is t o be removed, do not t ouch the met al  

parts of the unit . It may cause an injur y.

CAUTION

Do not clean the air conditioner with w

ater. W ater ma y enter 

the unit and degrade the insula tion. It ma y cause an electric 

shock.

CAUTION

Ventila te the room well  when used t ogether with a  st ove, 

et c. An oxygen short age may occur.

CAUTION

When the unit is t o be cleaned, swit ch off and turn off the 

circuit breaker. Do not clean unit when power is on as it ma

cause fire and electric shock. It ma

y also cause an injur y.

CAUTION

Do not put a  pet or house plant where it will

 be exposed t o 

direct air flow . This could injure the pet or plant

.

CAUTION

Do not use for special  purposes. Do not use this air condi -

tioner t o preser ve precision devices, food, pets, plants, and 

art objects. It ma y cause deteriora tion of quality , et c.

CAUTION

Hold the plug by  the head of the power plug when t aking it 

out. It may cause electric shock and damage.

CAUTION

Turn off the main power swit ch when not using the unit for a  

long time. It ma y cause f ailure of product or fire.

Содержание distinctions DCP073A25AA

Страница 1: ...f you service this unit you assume responsibility for any injury or property damage which may result In addition in jurisdictions that require one or more licenses to service the equipment specified i...

Страница 2: ...nse a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual are intended as supplemental to existin...

Страница 3: ...ere it will not be tripped over SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed Incor rect operation due to ignoring in...

Страница 4: ...assemble or modify unit It may cause f ailure and electric shock CAUTION When the air fil ter is t o be removed do not t ouch the met al parts of the unit It may cause an injur y CAUTION Do not clean...

Страница 5: ...ppliance Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord Electrical Informa tion Be sure the electrical service is adequ...

Страница 6: ...start back up in the mode and configuration it was in when power was lost Aut omatic Ev apora t or Freeze Protection The compressor is turned off automatically to keep the evaporator from freezing an...

Страница 7: ...r fan motors starts before the compressor and stops after the compressor cycles off 3 Push the S1 on the DIP SWITCHES to UP ON position 4 When frost builds up to the evaporator coils the unit will def...

Страница 8: ...ed to be operated under condition as follows Outdoor Temp 18 43 C 64 109 F 18 52 C 64 125 F for special tropical models Indoor Temp 17 32 C 62 90 F Outdoor Temp 5 24 C 23 76 F Indoor Temp 0 27 C 32 80...

Страница 9: ...ABLE 1 DIP SWITCH CONFIGURATIONS NOTE On heating mode the setting tempera ture can not be higher than 29 C 84 F Wall Thermost at Enable A wired wall thermostat can be connected to the unit If it is th...

Страница 10: ...Switches 2 use types of wall thermostat 1 use PTAC other wall thermostat 0 control panel enable You can consult with the sales agency or manufacturer for details 2 65 F 78 F 18 C 26 C 1 63 F 80 F 17 C...

Страница 11: ...r under NEVER through the w all sleeve The wire should then be routed behind the front panel t o the easil y accessible terminal connect or Figure A Proper Wiring Routing Beneath Unit NOTE Refer t o t...

Страница 12: ...signal from FC L and FC N input called front desk control Input must be 24VAC If system doesn t receive a 24VAC signal it will turn unit off otherwise the unit runs in normal control The DIP switch c...

Страница 13: ...be dra wn int o room This will reduce hea ting or cooling efficiency Lift unit level and slide unit into wall sleeve until firmly against front of wall sleeve and secure with 4 screws and washers sup...

Страница 14: ...ters in place or with damaged fil ter will allow dirt and dust t o reach in door coil and reduce cooling heating airflow and efficiency of unit Airflow restriction ma y cause damage t o unit The most...

Страница 15: ...eck dip switch and wall thermostat settings for desired comfort Vent door left open Wait approximately 3 minutes for compressor to start Unit may be in protection mode Compressor is in time delay The...

Страница 16: ...an the evaporator once every three months by professional people NOTES 1 If circuit breaker is tripped or fuse is blown more than once contact a qualified electrician 2 If unit is installed where cond...