PACKAGED TERMINAL 

AIR CONDITIONER / HEAT PUMP

INSTALLATION INSTRUCTIONS

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to know 
the product better than the customer. This includes all safe-
ty precautions and related items.

Prior to actual installation, thoroughly familiarize yourself 
with this Instruction Manual. Pay special attention to all 
safety warnings. 

Often during installation or repair it is possible to place 
yourself in a position which is more hazardous than when 
the unit is in operation.

Only personnel that have been trained to install, adjust, 

service or repair(hereinafter, “service”) the equipment spec

-

ified in this manual should service the equipment.  The manu

-

facturer will not be responsible for any injury or property 

damage arising from improper service or service proce

-

dures.  If you service this unit, you assume responsibility for 

any injury or property damage which may result.  In addition, 

in jurisdictions that require one or more licenses to service 

the equipment specified in this manual, only licensed per

-

sonnel should service the equipment.  Improper installation, 

adjustment, servicing or repair of the equipment specified 

in this manual, or attempting to install, adjust, service or 

repair the equipment specified in this manual without proper 

training may result in product damage, property damage, 

personal injury or death.

WARNING

Before using your air conditioner, please read this man-

ual carefully and keep it for future reference.

This manual must be left with the owner of the 

equipment.

IO-930
05/2022

Model:

DCP073A25AA

DCP073A35AA

DCP093A25AA

DCP093A35AA

DCP123A35AA

DCP123A50AA

DCP153A35AA

DCP153A50AA

DHP093A25AA

DHP093A35AA

DHP094A35AA

DHP123A35AA

DHP123A50AA

DHP124A35AA

DHP153A35AA

DHP153A50AA

PTAC Direct Sales, Inc.

185 S.. Kimball Av

 

Suite 1

30 

Southlake, T

X

 76092

 

877.454.7822 (T)

877.647.6408 (F)

Содержание distinctions DCP073A25AA

Страница 1: ...f you service this unit you assume responsibility for any injury or property damage which may result In addition in jurisdictions that require one or more licenses to service the equipment specified i...

Страница 2: ...nse a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual are intended as supplemental to existin...

Страница 3: ...ere it will not be tripped over SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed Incor rect operation due to ignoring in...

Страница 4: ...assemble or modify unit It may cause f ailure and electric shock CAUTION When the air fil ter is t o be removed do not t ouch the met al parts of the unit It may cause an injur y CAUTION Do not clean...

Страница 5: ...ppliance Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord Electrical Informa tion Be sure the electrical service is adequ...

Страница 6: ...start back up in the mode and configuration it was in when power was lost Aut omatic Ev apora t or Freeze Protection The compressor is turned off automatically to keep the evaporator from freezing an...

Страница 7: ...r fan motors starts before the compressor and stops after the compressor cycles off 3 Push the S1 on the DIP SWITCHES to UP ON position 4 When frost builds up to the evaporator coils the unit will def...

Страница 8: ...ed to be operated under condition as follows Outdoor Temp 18 43 C 64 109 F 18 52 C 64 125 F for special tropical models Indoor Temp 17 32 C 62 90 F Outdoor Temp 5 24 C 23 76 F Indoor Temp 0 27 C 32 80...

Страница 9: ...ABLE 1 DIP SWITCH CONFIGURATIONS NOTE On heating mode the setting tempera ture can not be higher than 29 C 84 F Wall Thermost at Enable A wired wall thermostat can be connected to the unit If it is th...

Страница 10: ...Switches 2 use types of wall thermostat 1 use PTAC other wall thermostat 0 control panel enable You can consult with the sales agency or manufacturer for details 2 65 F 78 F 18 C 26 C 1 63 F 80 F 17 C...

Страница 11: ...r under NEVER through the w all sleeve The wire should then be routed behind the front panel t o the easil y accessible terminal connect or Figure A Proper Wiring Routing Beneath Unit NOTE Refer t o t...

Страница 12: ...signal from FC L and FC N input called front desk control Input must be 24VAC If system doesn t receive a 24VAC signal it will turn unit off otherwise the unit runs in normal control The DIP switch c...

Страница 13: ...be dra wn int o room This will reduce hea ting or cooling efficiency Lift unit level and slide unit into wall sleeve until firmly against front of wall sleeve and secure with 4 screws and washers sup...

Страница 14: ...ters in place or with damaged fil ter will allow dirt and dust t o reach in door coil and reduce cooling heating airflow and efficiency of unit Airflow restriction ma y cause damage t o unit The most...

Страница 15: ...eck dip switch and wall thermostat settings for desired comfort Vent door left open Wait approximately 3 minutes for compressor to start Unit may be in protection mode Compressor is in time delay The...

Страница 16: ...an the evaporator once every three months by professional people NOTES 1 If circuit breaker is tripped or fuse is blown more than once contact a qualified electrician 2 If unit is installed where cond...

Отзывы: