36
•
Profile D
ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airflow. Profile D
has a 1/2 minute at 50% airflow OFF delay.
OFF
OFF
Figure 50
Model
Tap
Low
Stage
Cool
High
Stage
Cool
Low
Stage
Heat
High
Stage
Heat
A
403
596
422
494
B
527
796
471
553
C
675
974
521
601
D
803
1192
574
676
A
398
599
667
953
B
557
817
740
1059
C
696
1007
808
1158
D
810
1212
881
1260
A
403
629
855
1202
B
540
806
923
1316
C
705
1023
1033
1389
D
819
1230
1063
1396
A
513
789
867
1228
B
660
967
939
1337
C
791
1182
1016
1430
D
913
1375
1077
1516
A
564
820
1256
1818
B
784
1133
1292
1870
C
982
1464
1316
1910
D
1259
1736
1358
1957
A
547
867
1329
1891
B
831
1160
1362
1940
C
1020
1467
1390
1968
D
1278
1910
1440
2028
A
449
655
682
957
B
569
807
750
1059
C
716
998
820
1155
D
854
1207
888
1251
A
433
656
687
938
B
541
790
751
950
C
686
972
814
986
D
806
1195
874
992
A
405
624
758
1057
B
549
808
815
1146
C
678
994
882
1256
D
784
1177
946
1349
A
556
837
889
1234
B
714
1022
944
1325
C
838
1206
1019
1442
D
991
1475
1068
1528
A
524
784
1209
1759
B
744
1078
1249
1797
C
927
1388
1277
1840
D
1185
1766
1300
1881
A
540
854
1284
1744
B
870
1123
1310
1827
C
1000
1399
1350
1860
D
1235
1804
1388
1918
*CVC960403BN*
*CVC960603BN
*CVC960803BN
*CVC960804CN*
*CVC961005CN*
*CVC961205DN*
*M VC960403BN*
*MVC960603BN*
*MVC960803BN*
*MVC960804CN*
*MVC961005CN*
*MVC961205DN*
Airflow Table
7.
Select the heating speed for your model from the heating
speed chart in the Specification Sheet. The adjust setting
(already established by the cooling speed selection)
determines which set of speeds are available. The selected
speed must provide a temperature rise within the rise
range listed with the particular model.
Example:
If the *MVC960804CN** is set for 1210 CFM
on cooling, the “ADJUST” is set to “+” (plus).
The four heating speeds available are “A
Plus”, “B Plus”, “C Plus”, and “D Plus”. “A
Plus” has a rise of 46
°
F for both stages which
is within the 30-60°F rise range for the
*MVC960804CN**. This setting will keep
electrical consumption to a minimum. Set
the “Heat” speed DIP switches to “A”.
3
4
A
OFF
OFF
B*
ON
OFF
C
OFF
ON
D
ON
ON
Switch Bank: S4
Heating
Airflow
DIP Switch No.
(*Indicates factory setting)
8. Select the desired “heating” speed tap by positioning
switches S4- 3,4 appropriately. Refer to figure above.
Verify CFM by noting the number displayed on the dual 7-
segment LED display.
In general lower heating speeds will: reduce electrical consump-
tion, lower operating sound levels of the blower, and increase the
outlet air temperature delivered to the home. The speeds avail-
able allow the blower performance to be optimized for the par-
ticular homeowner’s needs.
B
LOWER
H
EAT
O
FF
D
ELAY
T
IMINGS
The integrated control module provides a selectable heat off de-
lay function. The heat off delay period may be set to 90, 120,
150, 180 seconds using the DIP switches or jumper provided on
the control module. The delay is factory shipped at 150 seconds
but may be changed to suit the installation requirements and/or
homeowner preference. Refer to the following figures for switch
positions and corresponding delay times.
1
2
90 seconds
OFF
OFF
120 seconds
ON
OFF
150 seconds *
OFF
ON
180 seconds
ON
ON
Heat OF F Delay
DIP Switch No.
Switch Bank: S1
(*Indic ates factory setting)
Heat Off Delay Dip Switches
Содержание *CVC96
Страница 53: ...53 THIS PAGE LEFT INTENTIONALLY BLANK...