FURNACE SPECIFICATIONS
7
*CSS96
„ Natural
Gas
BTU/h
†
‡
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
"
FPT
and noise issues.
greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence
over clearances from the enclosure where accessibility clearances are greater.
*CSS96
0402BNA
*CSS96
0603BNA
*CSS96
0804CNA
*CSS96
1005CNA
*CSS96
1205DNA
High Fire Input„
40,000
60,000
80,000
100,000
120,000
High Fire Output„
38,400
57,600
76,800
95,000
114,000
AFUE†
96
96
96
95
95
Temperature Rise Range ( F)
25 - 55
35 - 65
35 - 65
40 - 70
45 - 75
Vent Diameter‡
2" - 3"
2" - 3"
2" - 3"
2" - 3"
3"
No. of Burners
2
3
4
5
6
Circulator Blower
Available AC @ 0.5" ESP
1.5 - 3
1.5 - 3
2.5 - 4
3 - 5
3 - 5
Size (D x W)
10" x 8"
10" x 8"
10" x 10"
11" x 10"
11" x 11"
Horsepower @ 1075 RPM
‰
Speed
4
4
4
4
4
Filter Size (in†)
Permanent
427
512
683
768
844
Disposable
213
256
341
384
422
Electrical Data
Min. Circuit Ampacity
9.6
9.6
12.8
13.7
13.7
15
15
15
15
15
Shipping Weight (lbs)
N/A
N/A
N/A
N/A
N/A