Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RT2310011 Rev. 0
September 1999
4
Converting from Natural Gas to LP Gas
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap with a wrench.
2. Reverse pressure regulator cap.
•
Cap must show “LP”.
3. Place pressure regulator cap on pressure regulator
and tighten.
A
LP
A
Cap
Converting Surface Burners for Use with
LP/Propane
1. Remove 5 control knobs from range.
•
Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
•
Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
•
After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside.
•
Gas valve and orifice hood are visible after burner
control panel is removed.
A
B
C
D
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
D—Screw
4. While facing range front, turn orifice hoods
counterclockwise 1½ to 2 turns or until snug.
•
Use ½ inch open end or 90° offset open end
wrench.
•
Do not over tighten orifice hoods. If orifice hoods
are over tightened, gas supply can be cut off or
orifice hoods can strip.
5. Open air shutter fully.
A
B
Open Fully
A—Orifice Hood
B—Air Shutter