COMPONENTS TEST
PROCEDURES
RESULTS
FAN MOTOR
DAMPER MOTOR
CIRCULATION
MOTOR
VENTILATION MOTOR
SYNCHRONOUS
MOTOR
THERMISTOR
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
1. Remove the connector from PCB.
2. Measure resistance across pins 1 & 3.
(ohm meter scale: Rx1)
Normal:
Approximately
Abnormal:
Infinite or several.
Normal:
Approximately 25 to 45 ohm
Normal:
Approximately 3 to 4 Kohm
Abnormal:
Infinite or several.
Normal:
Approximately
250 to 350 Kohm at 68 ± 35°F
Abnormal:
Infinite or several.
Fan
35-55
ohm
Damper
2.5-3.5
Kohm
Cir
25-40
ohm
7-18
Содержание AMV6177AAB
Страница 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL For Model AMV6177AAB AMV6177AAQ AMV6177AAS AMV6177AAW ...
Страница 11: ...5 3 MATRIX CIRCUIT FOR TOUCH KEY BOARD For Model AMV6177AAB AMV617AAQ AMV6177AAS AMV6177AAW ...
Страница 37: ...7 25 PROBLEM F No buzzing when touching the key between stages or at end of cooking 1 ...
Страница 38: ...7 26 PROBLEM G Ventilation fan does not operate when FAN HIGH LOW key is touched 1 Check 1 POWER SUPPLY 2 FUSE ...
Страница 43: ...8 5 EV 4001 4000 4002 W111 4003 4002 4004 LATCH BOARD PARTS ...
Страница 47: ...8 9 EV VINYL BAG 6011 6009 6010 6008 INSTALLATION PARTS ...
Страница 48: ...Printed in Korea P NO 3828W5S4606 ...